Specifications
Interleaf EP1052 TROUBLESHOOTING
96.11.01
T-30
C004C
Step
Check Item Result Action
1
Is M9 turning at low speed when the
Power Switch is in the ON position?
NO
Begin with step 3.
Does the voltage across PJ6A-9 on
PWB-A and GND change from DC12V
YES
Replace M9.
2
to DC24V when the Start Key is
pressed?
NO
Replace PWB-A.
Is the voltage across PJ6A-9 on PWB-
YES
Replace M9.
3
A and GND DC12V when the Power
Switch is in the ON position?
NO
Replace PWB-A.