19-3. Synchronizing Roller Control
The Synchronizing Rollers are started as Synchronizing Roller Clutch CL1 is
energized upon reception of a signal from PWB-A.
Control Signal Energized Deenergized WIRING DIAGRAM
CL1 PWB-A PJ6A-4 L H 2-N
Control Signal Blocked Unblocked WIRING DIAGRAM
PC54 PWB-A PJ18A-2 L H 14-D