Specifications

Interleaf EP1052 SWITCHES ON PWBs/TECH. REP. SETTINGS
96.11.01
S-5
<Clearing Procedures>
D Initialize Points PJ2
1. Turn OFF the Power Switch.
2. With PJ2 closed, turn ON the Power Switch.
3. In approx. 5 sec., open PJ2.
D Memory Clear Test Point TP2
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and 2 closed, turn ON the Power Switch.
3. In approx. 5 sec., open the circuit across TP1 and 2.
NOTE
D If an erratic operation or display occurs, perform the clearing procedures in the order of PJ2 and TP2.
D When memory clear has been performed, make the necessary settings again.
<List of Data Cleared by Switches and Points>
Clearing Means
Data Cleared
Front Door
Open/Close
Trouble Reset
Switch
(S1)
Initialize
Points
(PJ2)
Memory Clear
Test Point
(TP2)
Misfeed display f f f f
Malfunction display
(excluding Exposure Lamp
and fusing malfunctions)
f f f f
Malfunction display
(including Exposure Lamp and
fusing malfunctions)
* f f f
Erratic operation/display * * f f
User mode * * * f
Service mode * * * f
F3/5/8 adjustment values * * * f
Adjust mode * * * f
f : Cleared * : Not cleared