Specifications

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 MECHANICAL/ELECTRICAL
98.04.24
M-59
1174SBM1503A
The Synchronizing Rollers are started as the Synchronizing Roller Clutch is energized
upon reception of a signal from the Master Board.
t: The value of t depends on the settings made in Adjust Mode.
15-3. Synchronizing Roller Control
Control Signal Energized Deenergized WIRING DIAGRAM
CL1 PWB-A PJ5A-4A L H 4-A
Control Signal Blocked Unblocked WIRING DIAGRAM
PC54 PWB-A PJ17A-2A L H 4-D
1174T17MCA