Installation guide
Advanced Error Handling 
 MN1270 02.2002  21 
vel
DECEL rate
ERRORDECEL rate
time
error input
axis status
axis error
error handler
#1 #2#3 #4 #5
#1 : Error input activated 
#2 : Error input deactivated 
#3 : Desired action completed and error handler called 
#4 : Error cancelled 
#5 : Error handler completes 
While an error is present the handler will continue to be called every 2ms. 
In previous versions of Mint, in the event of an asynchronous error Mint has always dropped the relay. 
This functionality has been removed and any changes to the outputs are controlled by the Mint Motion 
Library. 
In order to maintain backwards compatibility in functionality a new function has been introduced which 
allows the user to specify a global error output with will be dropped in the event of an error. This 
output can be any of the digital outputs including the relay. 
This error output is set using the keyword 
GLOBALERROROUPUT. 
5.2 Miscellaneous Errors 
Miscellaneous errors are non axis dependant asynchronous error conditions. They are represented as a 
bit pattern as follows: 
Bit Symbol  Meaning 
0  me12V  12 volt rail failure 
1  meOUTPUT_FAULT0  Output short circuit for bank 0 
2  meOUTPUT_FAULT1  Output short circuit for bank 1 
3  meOUTPUT_FAULT2  Output short circuit for bank 2 
4  meRS232_RECEIVE_OVERRUN  RS232 receive overrun 
5  meRS232_TRANSMIT_OVERRUN  RS232 transmit overrun 
6  meRS232_RECEIVE_ERROR  RS232 receive framing error 
7  meCAN_RECEIVE_OVERRUN  CAN serial redirection receive overrun 
8  meSERVO_TICK_OVERRUN  The servo loop or profiler have exceeded their 
timeslice 
9  meRS485_RECEIVE_OVERRUN  RS485 receive overrun 
10  meRS485_TRANSMIT_OVERRUN  RS485 transmit overrun 
11  meRS485_RECEIVE_ERROR  RS485 receive framing error 