Installation guide
Keyword Reference Guide 
 MN1270 02.2002  57 
CURRENTLIMITMODE/CLM 
Purpose: 
To set and read the how the I
2
T current limiting operates. 
Controllers Supported: 
NextMove PCI  NextMove PC  NextMove BX  MintDrive  ServoNode 51 
 
Format: 
CURRENTLIMITMODE[axes] = <expression> {,<expression> ...}
v = CURRENTLIMITMODE[axis]
Dot Parameters: 
Axis - Axis No. 
Attributes: 
Controller Read Write Command Multi-
Axis 
Scaled Default  Range 
MintDrive 
   
 
 0 
0 ≤ x ≤ 1 
Description: 
The following modes exist: 
•  0 - Ignore (I
2
T is not enabled); 
•  1 - Fold Back (Demand current is folded back to the continuous current when the I
2
T limit is 
reached). 
See also: 
CURRENTLIMIT, CURRENTLIMITAREA, CURRENTLIMITTIME 
CURRENTLIMITTIME/CLT 
Purpose: 
Sets or reads the I
2
T time. 
Controllers Supported: 
NextMove PCI  NextMove PC  NextMove BX  MintDrive  ServoNode 51 
 
Format: 
CURRENTLIMITMODE[axes] = <expression> {,<expression> ...}
v = CURRENTLIMITMODE[axis]
Dot Parameters: 
Axis - Axis No. 
Attributes: 
Controller Read Write Command Multi-
Axis 
Scaled Default  Range 
MintDrive 
   
 
 1000 
0 ≤ x ≤ 30000 
Description: 
Reads or sets the maximum time that the demand current can equal the peak current before folding 
back. 
See also: 
CURRENTLIMIT, CURRENTLIMITAREA, CURRENTLIMITMODE 