Installation guide
Keyword Reference Guide 
 MN1270 02.2002  67 
No.  Parameter name  Mint Keyword  Range  Factory 
Default 
Units 
1601 Resolver Align 
MOTORALIGNMENT
0 to 360  Calculated 
value 
Degrees 
1602 UVW Alignment 
MOTORPHASEOFFSET
0 to 360  Calculated 
value 
Degrees 
1603 Speed Filter 
MOTORSPEEDFILTER
0 to 7  Calculated 
value 
1604 Feedback Align 
MOTORDIRECTION
0 – Forward 
1 – Reverse 
0 
1605  Current Prop Gain 
KIPROP
0 to 1000  50   
1606  Current Int Gain 
KIINT
0 to 400  150  Hz 
1607  Speed Prop Gain 
KVPROP
0 to 1000  10   
1608  Speed Int Gain 
KVINT
0 to 9.99  1.00  Hz 
1611  Motor Inductance (line to 
line) 
MOTORINDUCTANCE
0 to 98.3  Motor 
Dependent 
mH 
2002  Max Output Speed 
MOTORSPEEDMAX
0 to 22500  Rated 
Motor 
Speed 
RPM 
2003  Peak Current Limit 
MOTORPEAKCURRENT
0 – Peak 
Rated Current 
Peak 
Control 
rating 
Amps 
2501  Motor Rated Amps 
MOTORRATEDCURRENT
0 to 999.9  Factory Set  Amps 
2502  Motor rated Poles 
MOTORPOLES
0 to 100  4  Poles 
2503 Feedback Type 
MOTORFEEDBACK
0 – Resolver
1 – UVW 
Encoder 
2 – Z Encoder 
0 
2504 Encoder Lines 
MOTORENCODERLINES
 1024  
2505 Resolver Speed 
MOTORRESOLVERSPEED
0 to 10  1   
See Also: 
DRIVEFAULT 
EFFORT/EF 
Purpose: 
Reads the instantaneous demand to the power stage of the drive. 
Controllers Supported: 
NextMove PCI  NextMove PC  NextMove BX  MintDrive  ServoNode 51 
 
Format: 
v = EFFORT
Attributes: 
Controller Read Write Command Multi-
Axis 
Scaled Default  Range 
ServoNode 51 
 
  0 
-100 ≤ x ≤ 100 
Description: 
Reads the instantaneous demand to the power stage. EFFORT is a percentage of the maximum 
demand that can be applied to the power stage. It can also be accessed via high speed 
capture. 