After Use
When finished scrubbing, lift the scrub deck and turn the solution lever off, water flow will cease. Lift the rear
squeegee (the vacuum motor will turn off). Move the machine to a service area for daily maintenance and
review items that may need service.
Empty the solution tank, by disconnecting the solution tank drain hose from the barb fitting over a drain.
Rinse the tank with clean water to prevent any build-up of dried chemicals that could clog the plumbing.
Empty and clean the recovery tank by flushing with a hose. Be sure to also clean the float shut off screen.
Remove the brushes or pad holders and rinse them in warm water and hang to dry.
Remove the rear squeegee, rinse with warm water and reinstall after cleaning.
Check the maintenance schedule in the next section and perform any required maintenance before storing
the machine.
Store the machine indoors in a clean dry place. Keep from freezing. Leave solution and recovery tank lids
open for ventilation to prevent odor build-up.
Turn Key switch OFF (O) and remove key.
Have a qualified service technician check the vacuum motor carbon motor brushes once a year or after 300 operating hours.
The brush motor carbon brushes should be checked every 500 hours or once a year.
NOTE: Refer to the Service Manual for more detail on maintenance and service repairs.
Regularly scheduled lubrication of certain machine parts should be performed to insure trouble-free
operation of the machine. Apply a generous amount of grease into the fittings on the machine until grease
seeps out around the bearings.
The grease points are listed below:
Rear squeegee caster wheel axle (2)
Rear squeegee caster swivel (2)
Apply lubricant or light machine oil to lubricate the:
Rear squeegee general pivot points
Scrub deck linkages
Daily Weekly Monthly Yearly
Charge Batteries
Check Each
Battery Cell(s)
Water Level
Lubrication –
Grease Fittings
Check Carbon
Brushes
Check/Clean Tanks
& Hoses
Inspect Scrub
Housing Skirts
Check/Clean/Rotate
the Brushes/Pads
Inspect and
Clean Solution
Filter
Check/Clean the
Squeegee
Check/Clean
Vacuum Shut-Off
Float in Recovery
Tank