Technical information
11.14
Request the latest literature and guides from Anixter.
1.800.ANIXTER • anixter.com/literature
Power Supplies and Protection
Altronix
Power Supplies and Protection
D
Power Supplies;General Purpose/3084
Index1.Networking Systems//Video Products//Video Security Systems
ALTRONIX PR23151V2-160618.tif
These units convert one 12 to 24 V AC or DC input into eight independently controlled
fused or PTC protected outputs. These power outputs can be converted to dry Form
"C" contacts (ACM8 and ACM8E only). Outputs are activated by an open collector sink
or normally open (N.O.) dry trigger input from an access control system, card reader,
keypad, push button, PIR, etc. The unit will route power to a variety of access control
hardware devices including mag locks, electric strikes, magnetic door holders, etc.
Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to
be powered by one common power source which will provide power for both the board
operation and locking devices, or two totally independent power sources, one
providing power for board operation and the other for lock/accessory power. The FACP
interface enables emergency egress, alarm monitoring or may be used to trigger other
auxiliary devices. The fire alarm disconnect feature is individually selectable for any
or all of the eight outputs.
FEATURE
S
•12 to 24 volt AC or DC operation (setting not required, 0.6 amp @ 12 volt,
0.3 amp @ 24 volt current consumption with all relays energized)
•Power supply input options: a) One common power input (board and lock power)
b) Two isolated power inputs (one for board power and one for lock/
hardware power)
•Eight access control inputs
•Eight independently controllable outputs
•Eight auxiliary power outputs (unswitched)
•Fire alarm disconnect (latching or non-latching) selectable by output
•Removable terminal blocks facilitate ease of installation
Power Supplies;General Purpose/3289
Index1.Networking Systems//Video Products//Video Security Systems
ALTRONIX PR23158V2-160643.tif
These Altronix Power Supplies distribute and route power to access control systems
and accessories. They will convert a 115 V AC 50/60 Hz input into eight
independently controlled fuse or PTC-protected Class 2 power limited 12 V DC or 24 V
DC outputs. These outputs can also be configured as dry Form "C" contacts. Outputs
are activated by an open collector sink or normally open (N.O.) dry trigger input from
an access control system, card reader, keypad, push button, PIR, etc. The unit will
route power to a variety of access control hardware devices including: mag locks,
electric strikes, magnetic door holders, etc. Outputs will operate in both Fail-Safe
and/or Fail-Secure modes. The FACP Interface enables emergency egress, alarm
monitoring or may be used to trigger other auxiliary devices. The fire alarm
disconnect function can be configured for the following modes; a) Eight outputs
affected. b) Four outputs affected and four outputs unaffected (50/50 mode).
FEATURE
S
•UL Listed for access control (UL 294)
•C(UL) Listed
•Input 115 V AC 60 Hz
•Eight access control inputs
•Eight independently controllable outputs
•Eight auxiliary power outputs (unswitched)
•Fire alarm disconnect (latching or non-latching) selectable by output
•AC input and DC output LED indicators
•AC fail, battery fail and battery presence supervision
•Removable terminal blocks facilitate ease of installation
Access Power Controller
Anixter No. Vendor No. Description
231068 ACM8 8-zone fused access power controller
274069 ACM8E 8-zone fused access power controller, with
enclosure (UL 294)
243299 ACM8CB 8-zone PTC access power controller
274070 ACM8CBE 8-zone PTC access power controller, with
enclosure (UL 294)
Distributed Access Power Controllers with Power Supplies
Anixter No. Vendor No. Description
231027 AL400ULACM 4 amps @ 12 V DC or 3 amps @
24 V DC
231029 AL600ULACM 6 amps @ 12 V DC or 24 V DC
243300 AL1012ULACM 10 amps @ 12 V DC
258185 AL1024ULACM 10 amps @ 24 V DC
For PTC protected outputs add "CB" to end of part number.