Technical information
11.48
Request the latest literature and guides from Anixter.
1.800.ANIXTER • anixter.com/literature
Power Supplies and Protection
Tripp Lite
Power Supplies and Protection
D
(continued) Rack Power Distribution Units (PDUs)
3-PHASE PDUS
HOT-SWAPPABLE PDUS PR34504V2-256033.tif
Hot-swappable PDUs with manual transfer switch enable live-replacement of
standard UPS systems for maintenance with no interruption of connected server or
networking loads. Dual power cables support PDU connection to separate utility and
UPS power sources.
Uninterrupted Power Supplies (UPS);1-phase, Tripp Lite/14232
Index1.Support and Supplies//Power Protection//AC Power
TRIPP LITE PR13452V2-30327.tif
Line-interactive tower protection for servers, security equipment, networks and more.
Reliable battery backup plus AVR, surge, spike and line noise protection.
FEATURE
S
•Advanced automatic voltage regulation corrects brownouts and overvoltages
without consuming battery power
•USB and/or DB9 communications ports and included PowerAlert Software
provide complete power network monitoring and control
Uninterrupted Power Supplies (UPS);1-phase, Tripp Lite/14231
Index1.Support and Supplies//Power Protection//AC Power
TRIPP LITE PR13455V2-30328.tif
Line-interactive rack-mount protection for servers, security equipment, telecom
systems and more. Advanced automatic voltage regulation (AVR) corrects brownouts
and overvoltages without consuming battery power. Reliable battery backup plus
surge, spike and line-noise protection.
FEATURES
•Advanced automatic voltage regulation (AVR)
•Expandable runtime with optional external battery packs (denoted with "X" in
model number)
•High-density, rack-mountable designs offer maximum protection in minimum
rack space
•Up to four communications ports and included PowerAlert software provide
complete network power management and control
•Select models feature enhanced power factor rating to support larger loads
•MOD unit features hot-swappable power module and internal battery pack
enables maintenance with zero downtime
•Select models available with pre-installed SNMPWEBCARD (denoted with "N" in
model number)
Anixter No. Vendor No. Description
396502 PDU3VSR10H50 Switched PDU 0U vertical, 3-phase, 208 V
(21) C13 and (three) C19 IEC 309,
CS8365C 50 amp
396503 PDU3VSR10G60 Switched PDU 0U vertical, 3-phase, 208 V
(21) C13 and (three) C19 IEC 309, 60 amp
450352 PDU3VN3L1530 Monitored PDU 0U vertical, 3-phase, 208 V
(30) C13 and (six) C19 L15-30P
434943 PDU3VN10L2120 Monitored PDU 0U vertical, 3-phase, 208 V
(30) C13 and (six) C19 L21-20P
396505 PDU3VN10L2130 Metered PDU 0U vertical, 3-phase, 208 V
(30) C13 and (six) C19 L21-30P
396506 PDU3VN10L1520 Metered PDU 0U vertical, 3-phase, 208 V
(30) C13 and (six) C19 L15-20P
396507 PDU3VN10L1530 Metered PDU 0U vertical, 3-phase, 208 V
(30) C13 and (six) C19 L15-30P
396508 PDU3VN10G30 Metered PDU 0U vertical, 3-phase, 208 V
(30) C13 and (six) C19 IEC 309, 30 amp
396509 PDU3VN10H50 Metered PDU 0U vertical, 3-phase, 208 V
(30) C13 and (six) C19 CS8365C, 50 amp
396510 PDU3VN10G60 Metered PDU 0U vertical, 3-phase, 208 V
(30) C13 and (six) C19 IEC 309, 60 amp
Anixter No. Vendor No. Description
427379 PDUB15 2U, 8 outlets, compatible with 100-127 V
UPS up to 1,500 VA with NEMA 5-15P
427380 PDUB20 2U, 8 outlets, compatible with 100-127 V
UPS rated 2,200-2,600 VA with
NEMA 5-15P
427381 PDUB30 2U, 7 outlets, compatible with 100-127 V
UPS up to 3,000 VA with NEMA L5-30P
427384 PDUBHV10 2U, 8 outlets, compatible with 200-240 V
UPS up to 1,500 VA with C14 input cable
427385 PDUBHV20 2U, 8 outlets, compatible with 200-240 V
UPS rated 2,000 to 3,000 VA with
C20 input cable
Smart Advanced Line-interactive Tower UPS Systems
Anixter No. Vendor No. Capacity VA/watts
Run Time (Min.)
Full/Half Load
381506 SMART750 750/450 5.5/16
254395 SMART1500 1,500/980 7/20
SmartPro Advanced Line-interactive Rack-mount UPS Systems