PRO-E SERIES User's Manual Para Systems, Inc. 1455 Lemay Dr. Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-9011 Internet: minutemanups.com UPS Sizing: sizemyups.com PN - 34000226 Rev.
English PRO-E Series User's Manual 1. Introduction 2 2. Controls and Indicators 5 3. Installation 7 4. Operation 9 5. Troubleshooting 12 6. Replacing the Battery 13 7. Obtaining Service 16 8. Specifications 17 9. Configurable Parameters & Settings 18 10. Limited Product Warranty 19 11. Declaration of Conformity 21 © Copyright Para Systems, Inc.
CAUTION! To reduce the risk of electrical shock in conditions where Thank you for purchasing a MINUTEMAN power protection product. It has been designed and manufactured to provide many years of trouble free service. the load equipment grounding cannot be verified, disconnect the UPS from the AC wall outlet before installing a computer interface cable. Reconnect the power cord only after all signaling connections are made.
Receiving Inspection English English After removing your MINUTEMAN UPS from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored. The packing materials that your UPS was shipped in are carefully designed to minimize any shipping damage.
REAR PANEL 1 English English 10 2 120V Models 3 9 4 8 5 6 7 1. The Information/Rating Label. 2. The Battery Backup and Surge output power receptacles are NEMA 5-15R type (IEC 320 C13 sockets for 230V models). 3. The USB Communications Interface Port is for UPS monitoring and control. 4. The RS232 Communications Interface Port is for UPS monitoring and control. 5. The Dipswitches are for setting the Inverter output voltage. 6.
WARNING! DO NOT plug Power Strips or Surge Protection Devices into CONNECTING THE UPS TO AN AC SOURCE Plug the UPS into a two pole, three wire, grounded receptacle only. Do not use extension cords, adapter plugs, power strips or surge strips. CHECKING THE SITE WIRING FAULT After plugging in the UPS, check the Site Wiring Fault (SWF) LED on the rear panel of the UPS. If the SWF LED is illuminated, the UPS is plugged into an improperly wired AC outlet.
English ON BATTERY When the UPS is operating on the batteries, the On-Battery LED will blink and the audible alarm will sound once every 10-seconds. The alarm will stop once the UPS returns to the On-Line operation. LOW BATTERY WARNING The UPS will sound two beeps every five-seconds when the battery reserve runs low. This condition will continue until AC returns or the UPS shuts down from battery exhaustion.
English English Symptom Possible Cause UPS will not turn on On/Off/Test button not pushed UPS operates in Input AC circuit breaker is battery mode only, tripped even though there is normal AC present Fault LED is illuminated Site Wiring Fault LED is illuminated The On-line/OnBattery LED is illuminated, but there is no output UPS has detected an internal fault Incorrect service wiring UPS does not provide expected runtime The batteries may be weak or at the end of useful service life The UPS is being
PRO-E Model # PRO500E PRO500iE PRO700E PRO700iE PRO1100E PRO1100iE PRO1500E PRO1500iE Battery Model # 1-12V9Ah 2-12V7Ah 3-12V7Ah 3-12V9Ah Panasonic Part # LC-R129 LC-R127 LC-R127 LC-R129 Yuasa Part # REW45-12 NP 7-12 NP 7-12 REW45-12 BATTERY REPLACEMENT PROCEDURE PLEASE READ THE CAUTIONS AND WARNINGS BEFORE ATTEMPTING TO REPLACE THE BATTERIES Hot-swappable batteries mean that the batteries can be replaced without powering down the whole UPS system.
English English IF THE UPS REQUIRES SERVICE 1.Use the TROUBLESHOOTING section to eliminate obvious causes. 2.Verify there are no circuit breakers tripped. A tripped circuit breaker is the most common problem. 3.Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem call or fax MINUTEMAN Technical Support at the following numbers; Voice phone (972) 446-7363, FAX line (972) 446-9011 or visit our Web site at www.minutemanups.com the "Discussion Board".
English English (These items may require optional software or hardware) Function UPS ID Battery install date Battery life in days Factory Default PRO-E User Choices Up to 64 characters to define the UPS Date of Date of battery manufacture replacement month/day/year XX/XX/XXXX Up to 5 1826 characters Enable/ Disable auto restart Enabled Enable or Disable Set audible alarm state Enabled Enabled, at low battery, disabled Shutdown Type UPS output Description Use this function to uniquely identify
LIMITED PRODUCT WARRANTY DECLARATION OF CONFORMITY English EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Para Systems is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, cost of substitutes, claims by third parties, or otherwise.
Notes: English Page do not print 22 23