Owner's manual

SQ
SQUELCH Setting
Press Down Up
Instructions:
1. Press and release the SET' button until cursor starts to blink denoting it is
ready to accept parameter changes.
2. During blinking, press and release or button to decrease or increase the
squelch level.
3. Press the 'SET' button to confirm the change.
WARNINGS:
Decreased SQ level setting has higher sensitivity level resulting in longer, maximize
reception range.
Increased SQ level setting has lower sensitivity level resulting in shorter, limited
reception range.
!
!
SQ
SET
SET
Instructions:
NOTE:
(1) 961 frequencies can be user-defined and up to 8 frequencies can be
stored in Group 11.
1. Press and release the 'SET' button until both icon and group number start to
blink.
2. During blinking, press and release or button to group 11.
3. Press the 'SET' button until it stops at FRQ cursor.
4. Press 'SET' button again until the first 3 digit of frequency starts to blink denoting
FRQ it is ready to accept parameter changes.
5. During blinking, press or button to decrease or increase parameter value by
1MHz.
6. Press the 'SET' button to confirm the change. Once change is saved, the last 3 digits
of the frequency starts to blink.
7. During blinking, press or button to decrease or increase parameter value by
25KHz.
8. Press the 'SET' button to confirm the change.
9. Up to 8 different frequencies can saved and stored into Group 11- - 01 to 08.
Caution:
The 8 saved frequencies in group 11 may not be compatible and interference-free and
therefore, not recommended to be used simultaneously at the same venue.
User-Defined FREQUENCY Setting
Press
SET
SET
SET
SET
SET
14
15
Diversity Wireless SystemsDiversity Wireless Systems