Datasheet

Setting Input Gain Level
! Selectable AF GAIN between 12dB to -6dB with
3dB parameter up or down selection.
! Press MODE button until AF GAIN mode
appears.
! Press SET button once to activate function.
! Press SET button to select the desired
sensitivity level.
! Press MODE button to confirm and save the
change.
! The higher the sensitivity level, the lower the
dynamic range of input signals. Meanwhile noise
will increase, and the feedback problem will be
getting more serious. Please make sure
sensitivity level is set at proper level.
8
9
Wideband Handheld TransmitterWideband Handheld Transmitter
01 01
GRP CH
! Frequency Band, Group & Channel and
Frequency are factory pre-set, thus, its
parameter values are displayed after it is ACT
synced. Values cannot be changed.
( )Frequency Band
( )Group and Channel
( )Frequency
7UA
BAND
718.275MHz
FREQUENCY
0 dB
AF GAIN
+3 dB
AF GAIN
+6 dB
AF GAIN
+12 dB +9 dB
AF GAIN AF GAIN
+9 dB
AF GAIN
+6 dB
-3 dB
AF GAIN
AF GAIN
+3 dB
-6 dB
AF GAIN
AF GAIN
0 dB
-3 dB
AF GAIN
AF GAIN