Solid Wall Installation
For installation onto a stud partition or laminated panel wall, or onto unfi xed rear-
entry pipework, refer to the next section: Stud Partition, Laminated Panel, or
Unfi xed Rear-entry Pipework Installation.
1. Make sure that the pipework is set
at the correct distance apart and
solidly fi xed as this supports the
valve. Apply suitable thread sealant
(not supplied) and attach the offset
connectors to the pipework in the
wall.
2. Tighten the offset connectors using
a spanner on the fl ats. Make sure
that the connectors are level and set
at the correct distance apart when
tightened.
3. Screw the concealing plates onto
the offset connectors until they come
into contact with the wall. Seal with
an appropriate sealant.
Pipework
Offset Connector
Wall
Spanner Flats
Offset Connectors
1/2" BSP Female
Connector
150mm
150mm