User guide
15
Bottom Cable
Channel
Top Cable
Channel
Thinned Section
of Case.
Thinned Section
of Case.
Full Case
Insert
Half Case
Insert
Full Case
Insert
Half Case
Insert
2. Conguring Inlet Supplies
The Mira Event XS is supplied with blanking plugs tted to all four ports of the inlet
manifold. The pipework conguration will determine which blanking plugs and case
inserts supplied must be tted to the case.
Supply Pipework Inlet Manifold Ports Case Inserts
Top Entry Inlet Fit blanking plugs to bottom
ports of the inlet manifold.
Fit half insert in the top inlet of
the case. Fit full insert in the
bottom inlet of the case.
Bottom Entry Inlet Fit blanking plugs to top ports
of the inlet manifold.
Fit full insert in the top inlet of
the case. Fit half insert in the
bottom inlet of the case.
Wall Entry Inlet Fit blanking plugs to bottom
ports of the inlet manifold.
Fit full insert in the top inlet of
the case. Fit full insert in the
bottom inlet of the case.
The Mira Event XS allows for electrical cable entry from the top, bottom or back of
the case. For top and bottom entries a thinned section of the case, covering the top
or the bottom cable channel, must be removed before the cable can be tted.