User guide
16
Cover Retaining
Screw
Cover Retaining
Screws
Push-t
Release
Tool
Temperature
Control Knob
Concealing
Cap
Temperature
Indicator
Blanking
Plug
Push-t
Release
Tool
Inlet
Manifold
This procedure removes the top two
blanking plugs from the inlet manifold
for top or wall entry pipe congurations.
Using this procedure as a guide, adjust
the steps for bottom entry congurations
as appropriate.
2.1. Remove the temperature knob
concealing cap.
2.2. Use the push-t release tool to lever
off the temperature knob.
Note! It will be easier to lever off
the temperature control knob with
the push-fit release tool inserted
under the knob directly below the
temperature indicator.
2.3. Unscrew the three cover retaining
screws sufficiently to remove the
cover.
Note! The cover retaining screws are
captive and need not be removed.
2.4. Insert the push-fit release tool
between the ange of each of the
blanking plugs and the collet of the
inlet manifold, and lever the plugs
outward. Whilst holding back on
the collet, pull out each appropriate
blanking plug by hand.