User guide
18
Trim the thinned
section of the case
covering
the cable channel.
Miniature
Trunking
All dimensions in millimetres
275
30
28
30
3.6. Using a spirit level position, the
appliance on the wall, then mark
through the three xing points.
Tip! Special consideration should
be given to the strength of the xing
arrangements when installing on to a
dry lined, stud partition or dry partition
wall structure. Installers may wish to
obtain alternative proprietary cavity
xings, or choose other options such
as fabricating rear supports using
wooden blocks, however, these
methods of fixing are beyond the
scope of this guide.
Warning! Ensure the marked xing
points are not inline with buried
cables and pipes before drilling.
3.7. Drill 9.5 mm holes and t the rubber
wall plugs supplied.
3.8. Cut away and trim the thinned section
in the top of the case to allow the
electrical supply cable to run down
cable channel in the back of the
case.
3.9. Run the electrical supply cable in
surface mounted miniature trunking
(not supplied). Allow sufficient
cable to connect to the Mira Event
XS terminal block (approximately
275 mm). Strip back approximately
30 mm of outer cable insulation.
3.10. Hot and cold inlet supply connections
as marked are:
Hot – Left, Cold – Right
Note! Supply connections must not
be connected in reverse.