User guide
27
Filter
Cap
Retaining
Screw
Use a silicone
based lubricant
to grease the 'O'
seals.
Filter Cap
4. Inlet Filter Cap, Cleaning – Removal and Installation
The following procedure can be applied for cleaning or renewing the inlet lter cap
or inlet lter cap ‘O’ seals.
Warning! Before proceeding, turn off the electrical and water supplies. The electricity
supply must be turned off at the mains and, if applicable, the appropriate circuit fuse
removed. Mains electrical connections are exposed when the cover is removed.
4.1. Remove the front cover, refer to
section: 'Maintenance, 3. Front
Cover – Removal'.
4.2. Unscrew the retaining screw and
remove the lter cap.
Note! A small amount of trapped
water may drain from the manifold.
4.3. Thoroughly clean both the inlet lter
meshes. Inspect the ‘O’ seals and
renew if required. Before retting the
inlet lter cap lightly grease ‘O’ seals
with a silicone based lubricant.
4.4. Ret components in reverse order.
4.5. Restore the water supplies and check
for any leaks.
4.6. Ret the cover and secure with the
three cover retaining screws, ret the
temperature knob and concealing
cap.
4.7. Restore the electrical supply.
4.8. Commission the Mira Event XS, refer
to section: 'Commissioning'.