User guide

28
5.1. Remove the front cover, refer to
section: 'Maintenance, 3. Front
Cover – Removal'.
5.2. Disconnect the electrical supply cable
from the terminal block.
5.3. Remove the exible hose from the
appliance.
5.4. Re move the t hree wall fixing
screws.
5.5. Using the push-t release tool, push
back and hold the collets from the
supply pipework, lift the Mira Event
XS from the wall to remove the supply
pipework from the inlet manifold.
5.6. Remove the screws securing the inlet
manifold and mixer assembly using
a T10 Torx screwdriver. Unclip the
pump transfer tube.
5.7. Remove the inlet manifold and mixer
assembly.
5.8. The ports adjacent to the mixer
assembly contain the inlet check
valves. The check valves can be
removed and replaced if required.
Ensure the check valve is inserted
with the ‘O’ seal on the check valve
facing into the outlet port of the
manifold.
Mixer
Assembly
Inlet
Manifold
Remove Securing
Screws
Transfer
Tube
5. Inlet Manifold, Check Valve - Removal and Installation
The following procedure can be applied to cleaning or renewing the inlet manifold,
inlet check valves or ‘O’ seals.
Warning! Before proceeding turn off the electrical and water supplies. The electricity
supply must be turned off at the mains and, if applicable, the appropriate circuit fuse
removed. Mains electrical connections are exposed when the cover is removed.