User guide

6
Valve Combinations
These thermostatic mixers are available with various shower ttings and water saving features, refer to
the table below to identify your mixer valve combination:
Mixer Valve
Shower
Fittings
Flow Regulator
Flow Rate Colour Comments
Moto EV /
Minilite EV
L14A 12 L/Min Red
Supplied in the component pack, designed to
be tted in the shower valve outlet
Pace EV /
Miniduo EV
L98B 12 L/Min Red
Supplied in the component pack, designed to
be tted in the shower valve outlet
Minilite BIV L14A 12 L/Min Natural
Supplied in the component pack, designed
to be tted between the shower hose and
RAC assembly
Minilite Eco EV L14A 6 L/Min Black
Factory tted in the shower valve outlet
(optional 8 L/Min (white/natural) flow
regulator supplied separately in the
component pack)
Minilite Eco BIV L14A 6 L/Min Black
Factory tted in the RAC assembly (optional
8 L/Min (white/natural) flow regulator
supplied separately in the component pack)
Miniduo BIV L98B
12 L/Min Natural
Supplied in the component pack, designed
to be tted between the shower hose and
RAC assemblyPace BIV L14D
Pace with Eco
Showerhead EV
L98B with Eco
Showerhead
7.0 L/Min Olive Green
Supplied in the component pack, designed
to be tted between the shower hose and
shower valve outlet
Miniduo with Eco
Showerhead EV
L98B with Eco
Showerhead
7.0 L/Min Olive Green
Supplied in the component pack, designed
to be tted between the shower hose and
shower valve outlet
Miniduo with Eco
Showerhead BIV
L98B with Eco
Showerhead
7.0 L/Min Olive Green
Supplied in the component pack, designed
to be tted between the shower hose and
RAC assembly
Miniduo with Eco
Showerhead BIR
Eco BIR
Showerhead
7.3 L/Min
Bright
Green
Supplied with the Eco BIR shower head,
designed to be tted between the wall plate
and inlet nipple
Flow regulators are supplied for installation on high pressure systems (above 0.5 bar).
For gravity fed or other low pressure systems do not t the ow regulator.
The Mira Minilite Eco has a ow regulator factory tted in the shower valve outlet or RAC assembly,
on older combination boiler systems it may be necessary to replace this 6 L/Min ow regulator with the
8 L/Min ow regulator (supplied), in order to achieve the minimum ow rate required to ignite and run
the boiler.
Important! The ttingof anyow regulatorto Paceand Miniduo models will invalidate TMV2
compliance due to the minimum ow rate requirements. Do not t ow regulators in TMV2
applications to these models.
For further information on how and where to t the ow regulator, refer to section: ‘Flow Regulators’.