AD JU ST L B A E R AN G E MIRA LOGIC SHOWER FITTINGS Installation & User Guide These instructions are to be left with the user 1
CONTENTS Introduction ............................................................................................. 3 Important Safety Information ................................................................. 4 Pack Contents Checklist ......................................................................... 5 Mira Logic ev and biv Shower Fittings .................................................. 5 Mira Logic biv Shower Right Angle Connector Fittings Pack ................
INTRODUCTION Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference.
IMPORTANT SAFETY INFORMATION Warning! 1. Products manufactured by us are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations. Caution! 1. Read all of these instructions. 2. Retain this guide for later use. 3. Pass on this guide in the event of change of ownership of the installation site. 4. Follow all warnings, cautions and instructions contained in this guide. 5.
PACK CONTENTS CHECKLIST 9 Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. Mira Logic ev and biv Shower Fittings 2 x Slide Bar End Supports 2 x Wall Plugs 2 x Fixing Screws 2 x Slide Bar End Caps 1 x Applicator 1 x Handset 1 x Clamp Bracket Assembly 1 x Slide Bar 2 x Hose Seals 1 x Hose Retaining Ring 1 x Soap Dish 2 x Soap Dish Wall Plugs 1 x 1.
Mira Logic biv Shower Right Angle Connector Fittings Pack 1 x Wallplate 2 x Wall Plugs 1 x Backplate 1 x Olive 1 x Backplate Nut 2 x Wallplate Screws 1 x Elbow 2 x Backplate Screws 2 x ‘O’ Seals 1 x Shroud Mira Logic bir Shower Fittings 1 x Mounting Plate 4 x Wall Plugs 4 x Mounting Plate Screws 1 x Backplate 1 x Top Cover 4 x BIR Screws 1 x BIR Assembly 1 x Olive 2 x Backplate Screws 1 x Backplate Nut 1 x ‘O’ Seal 4 x Cover Screws Documentation 1 x Ins
DIMENSIONS Mira Logic ev and biv Shower Fittings 344 mm Max. 659 mm 156 mm 44 mm 109 mm Mira Logic bir Shower Fittings 20° 20° 212 mm Max.
SPECIFICATIONS Minimum maintained pressure: with low capacity nozzle ring fitted (as supplied): 0.1 bar with high capacity nozzle ring fitted: 0.2 bar Maximum maintained pressure: 5.0 bar Warning! Exceeding the stated maximum maintained pressure could result in excessive spray forces and possible damage to the product. These are the typical flow performance graphs for the Mira Logic adjustable shower fittings only. There will be an additional pressure loss through the shower control.
INSTALLATION REQUIREMENTS Installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. 1. The hose retaining ring supplied must be used to stop the handset from dropping below the spill-over level of the bath or shower tray. This will prevent water supply contamination due to backsiphonage. 2.
INSTALLATION Note! For dry lined, stud partition, shower cubicle or laminated panel walls the installer may wish to obtain alternative proprietary cavity fixings. Use of these alternative fixings is beyond the scope of this guide. Important! If the Logic slide bar replaces an existing Mira slide bar make sure that the position of the shower control and the shower fittings provide a minimum of 25 mm between the handset and bath/tray spill-over level. This is necessary to prevent back-siphonage.
5. Make sure that the slots in the slide bar are aligned with the lugs in the support and fit the two slide bar supports to the ends of the slide bar. Make sure that each support is pushed firmly home. Note! If replacing an existing Mira Slide Bar proceed to instruction 8. 6. Using the assembled slide bar and supports as a template, mark the position of the two fixing holes using the centre slot. Warning! Make sure that there are no buried cables or pipes in the wall before drilling. 7.
Handset Installation 1. 2. 3. Caution! Do not overtighten the hose. Screw the hose onto the outlet of the shower control (Make sure that the hose washer is fitted). Pass the flexible hose through the hose retaining ring and screw the remaining end of the hose onto the handset (Make sure that the hose washer is fitted). Place the handset in the clamp bracket assembly. Handset Hose Washer Clamp Bracket Assembly Hose Retaining Ring Soap Dish Installation 1. 2. 3. 4. 5. 6.
Mira Logic Built-in Variable Shower Fittings (biv) Read the section: Installation Requirements before proceeding with the installation. The slide bar should be positioned to one side of the shower control at a convenient height for all the family. It should be positioned so that the handset discharges down the centre line of the bath, or across the opening of the shower cubicle. The handset should be directed away from the shower control. 15 mm Copper Pipe Solid and Dry-lined Wall Installation 1.
6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. Remove the backplate/wallplate assembly from the wall. Separate the backplate and the wallplate. Drill the two 6 mm wallplate holes. If necessary, make a recess 6 mm deep to accept the wallplate. Fit the two wall plugs supplied. Fit the wallplate to the wall with the two wallplate screws supplied. Temporarily fit the two backplate screws into the wallplate. This will prevent the fixing holes from becoming blocked with plaster or grout.
Shower Cubicle, Laminated Panel or Stud Partition Wall Installation 1. 2. 3. 4. 5. 6. 7. 8. 9. The 15 mm copper pipework from the outlet of the shower control must be vertical or horizontal, and not at an angle, so that it does not interfere with the installation screws. Drill a 25 mm hole in the wall for the copper pipework. Feed the copper pipework through the wallplate and then through the hole in the wall. The 15 mm copper pipework must protrude through the wall by 21-23 mm.
10. Check that the ‘O’ seal is fitted inside the backplate nut. Fit the olive and the backplate nut over the copper pipe and tighten the nut. Olive ‘O’ Seal (Inside) ‘O’ Seal (Outside) 11. Check that the second ‘O’ seal is fitted to the outside of the backplate nut. Press the elbow onto the backplate, make sure that the clips on the elbow engage with the backplate. Clips Backplate Nut Elbow 12. Press the shroud over the elbow, make sure that it engages with the lugs on the backplate. Shroud 13.
Mira Logic Built-in Rigid Shower Fittings (bir) Read the section: Installation Requirements before proceeding with the installation. The shower head should be positioned to one side of the shower control at a convenient height for all the family. It should be positioned so that the spray discharges down the centre line of the bath, or across the opening of the shower cubicle. The shower head should be directed away from the shower control. Solid and Dry-lined Wall Installation 1.
6. Remove the mounting plate/backplate assembly from the wall. 7. Separate the backplate and the mounting plate. 8. Drill the four mounting plate holes and fit the wall plugs supplied. 9. If necessary, make a recess 6 mm deep to accept the mounting plate. 6 mm Mounting Plate Backplate Screws 10. Fit the mounting plate to the wall with the four mounting plate screws supplied. The two threaded holes must be horizontal. 11. Temporarily fit the two backplate screws into the mounting plate.
16. Ensure that the ‘O’ seal is fitted on the backplate nut. Push the BIR assembly over the backplate nut onto the backplate. 17. Fix the BIR assembly to the backplate using the four cover screws provided. Note! If necessary, a 9 l/min flow regulator can be fitted in the BIR assembly with an adaptor – contact Customer Services. Backplate ‘O’ Seal BIR Assembly Cover Screws 18. Fix the upper shroud to the BIR assembly using the four self-tapping screws provided. Upper Shroud 19.
Shower Cubicle, Laminated Panel, or Stud Partition Wall Installation 15 mm Copper Pipe 1. The 15 mm copper pipework from the outlet of the shower control must be vertical so that it does not interfere with the installation screws. 2. Cut a 25 mm hole in the panel. 3. Cut two 5.5 mm holes at 48 mm centres in the panel. 4. Place the mounting plate behind the panel, and feed the copper pipe through the mounting plate and the panel. Make sure that the pipe protrudes 22–25 mm from the wall.
OPERATION Changing Spray Settings The handset has four different spray settings (Eco, start, soothe and force). 1. Eco Setting Turn the spray plate fully clockwise. Water will flow from the outer set of holes and the flow rate will be reduced. This setting performs best with most gravity, pumped, and mains pressure unvented systems. On electric showers and some combination boiler systems the economy setting will have no effect, and will give the same spray action as the start setting. 2.
Clamp Bracket Adjustment (ev and biv shower fittings only) Release Button 1. Depress the release button and slide the clamp bracket assembly to the required position. Clamp Bracket Assembly 2. Move the handset to the required angle. A friction mechanism within the clamp bracket assembly will hold the handset at the desired angle. Shower Head Adjustment (bir shower fittings only) 1. Move the spray head to the required position.
FAULT DIAGNOSIS The trouble shooting information tabled below gives details on what you can do as a user, should you encounter difficulties with the shower fittings whilst operating the shower. Before replacing any parts make sure that the underlying cause of the malfunction has been resolved. Malfunction Cause No flow or low flow Spray plate blocked. rate from shower fittings. Hose blocked or twisted. Remedy Refer to section: Maintenance, Cleaning. Clear blockage or release twist in hose or renew hose.
MAINTENANCE Cleaning Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning plated or plastic fittings. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth. Spray Plate Assembly - External 1. Use your thumb or a soft cloth to wipe any limescale from the soft rubber nozzles and the front face of the spray plate assembly. Spray Plate Assembly - Internal 1. Remove the spray plate assembly.
High Capacity Nozzle Ring Installation 1. Turn the adjuster anticlockwise. ring fully 2. Unclip and remove the adjuster ring. 3. Unscrew the spray plate assembly in an anticlockwise direction. The ‘O’ seals will provide some resistance. Inner Nozzle Retaining Ring 4. Remove the inner and outer nozzle retaining rings. Spray Plate Assembly 5. Replace the inner and outer nozzle rings with the high capacity versions supplied. 6. Ensure that the four ‘O’ seals are correctly fitted.
SPARES Mira Logic ev and biv Spares List 450.01 450.02 450.06 450.08 450.10 450.11 450.12 450.13 450.16 450.17 450.18 450.19 450.20 450.21 450.22 450.23 450.24 450.25 450.26 450.27 450.28 450.29 450.30 450.31 450.32 450.33 450.34 450.35 450.36 450.37 450.38 450.39 450.50 632.73 Hose 1.25 m – chrome Hose 1.
Mira Logic ev and biv Spares Diagram B 450.10 450.28 450.29 450.34 450.35 D C 450.36 450.37 450.38 450.39 450.21 450.22 450.23 450.06 450.24 450.25 450.16 C 632.73 450.01 450.02 450.18 D B 27 A 450.13 450.19 450.11 450.30 450.31 450.12 450.32 450.
Mira Logic bir Spares List 450.08 450.12 450.13 450.19 450.32 450.36 450.37 450.38 450.39 450.41 450.42 450.
ACCESSORIES DCV-H: An outlet double check valve, designed to prevent the backflow or backsiphonage of potentially contaminated water, through shower controls which are fitted with a flexible hose as part of the outlet shower fitting. The inclusion of the Mira DCV-H will increase the required supply pressure typically by 0.1 bar. Available as an optional accessory from Customer Services. DCV-H Outlet Double Check Valve (Part no 110.
NOTES 30
NOTES 31
CUSTOMER SERVICE Guarantee of Quality Spare Parts Mira Showers guarantee your product against any defect in materials or workmanship for the period shown in the Guarantee Registration Document included with your shower. Alternatively, to confirm the applicable guarantee period please contact Customer Services. To validate the guarantee, please return your completed registration card.