User guide
15
Shower Cubicle, Laminated Panel or Stud Partition Wall Installation
1. The 15 mm copper pipework from the
outlet of the shower control must be
vertical or horizontal, and not at an
angle, so that it does not interfere with
the installation screws.
2. Drill a 25 mm hole in the wall for the
copper pipework.
3. Feed the copper pipework through the
wallplate and then through the hole in
the wall. The 15 mm copper pipework
must protrude through the wall by
21-23 mm.
Note! If it is necessary to trim the pipe
to length, remove any burrs before
proceeding.
4. Place the backplate over the copper
pipe with the arrow pointing up. The
screw holes should be at 40° to the
horizontal.
5. Mark the positions of the two backplate
fixing holes.
6. Remove the backplate from the wall.
7. Drill the two 5.5 mm backplate holes.
8. Place the backplate over the copper
pipe with the arrow facing up.
9. Hold the wallplate in position behind
the wall. Insert the two backplate
screws through the holes in the wall
and fit them to the wallplate. Ensure
that the foam seal abuts the finished
wall surface.
Shower Control
15 mm Copper Pipe
Arrow
Backplate
Backplate Fixing
Holes
21–23 mm
15 mm Copper Pipe
Wallplate
Panel
Finished
Wall
Surface
Foam Seal
Backplate
Backplate
Screws
Copper Pipe
Arrow