User guide

17
Mira Logic Built-in Rigid Shower Fittings (bir)
Read the section: Installation Requirements before proceeding with the installation.
The shower head should be positioned to one side of the shower control at a convenient
height for all the family. It should be positioned so that the spray discharges down the
centre line of the bath, or across the opening of the shower cubicle. The shower head
should be directed away from the shower control.
23–25 mm
15 mm Copper Pipe
Mounting Plate
Backplate
Backplate
Screws
Shower Control
15 mm Copper Pipe
Solid and Dry-lined Wall Installation
1. The 15 mm copper pipework from the
outlet of the shower control must be
vertical so that it does not interfere with
the installation screws.
2. The 15 mm copper pipework must
protrude through the finished wall
surface by 21–23 mm.
Note! If it is necessary to trim the pipe
to length, remove any burrs before
proceeding.
3. Loosely screw the backplate to the
mounting plate using the two backplate
screws provided.
4. Place the mounting plate/backplate
assembly over the copper pipe.
5. Mark the position of the mounting plate
and the fixing holes on the wall
surface.