SPECIFICATIONS
Pressures
Minimum maintained pressure: 0.1 bar (10 kPa).
Maximum maintained pressure: 5.0 bar (500 kPa).
Warning! Exceeding the stated maximum maintained pressure could result in
excessive spray forces and possible damage to the product.
Installation must be carried out in accordance with these instructions, and must be
conducted by designated, qualied and competent personnel.
INSTALLATION REQUIREMENTS
1. The hose retaining ring supplied must be used to stop the showerhead from
dropping below the spill-over level of the bath or shower tray, ensure there is
a minimum of 25mm between the showerhead and bath/tray spill-over level.
This will prevent water supply contamination due to back-siphonage.
2. Installations must comply with UK Water Regulations/ Bye-laws (Scotland),
and Building and Plumbing Regulations in force at the time of installation
3. When installing the shower ttings in a cubicle, position with the spray pointing
across rather than toward the opening of the cubicle.
4. When installing the shower ttings over a bath, position with the spray pointing
down the centre line of the bath.
5. Avoid layouts where the shower hose will be sharply kinked. This may reduce
the life of the hose.
6. Do not t any form of ow control in the shower outlet.
7. Do not use excessive force when making connections.
8. Do not install the ttings in a position where it could become frozen.
Hose Retaining Ring
25 mm Minimum
Spill-over level