Operating instructions

GUIDE TO INSTALLATION AND OPERATION
IRD-3802 | 33
GSM Contribution
This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status
associated with this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm
provider for external applications. The possible values for this contribution are related to the Overall alarm
contribution:
If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution can be set to any
available value
If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is
forced to follow the Overall Alarm.
Log Events
iControl maintains a log of alarm events associated with the card. The log is useful for troubleshooting and
identifying event sequences. Click in the checkbox to enable logging of alarm events for each individual
alarm.
At the bottom of the window are several other controls
Copy to other cards
Click this button to open a panel that allows the
alarm configuration set for this card to be copied
into another IRD-3802 card.
Select one or more destination cards from the
list in the window by clicking in the
checkboxes, or all of them by clicking in the
All checkbox
Note that when you do a Copy Profile for this
card (see Sect.3.4.10), the alarm
configuration is copied along with all the other
settings.
Get alarm keys
Click this button to open a save dialog where you
can save a file containing a list of all alarms on
this card and their current values, along with an
Alarm Key for each. The alarm keys are useful
for system integration and troubleshooting.
The file is saved in Excel.csv format
OK, Apply, Cancel
OK accepts the settings and closes the window once the card confirms that there are no errors.
Apply accepts the settings, but leaves the window open
Cancel closes the window without applying any changes, and leaves the previous settings intact.
Figure 3.31 Get alarm keys save dialogue
Figure 3.30 Copy to other cards