Installation Instructions
1101 1/16
MACHINING:
MiraTEC trim can be grooved or machined to produce a variety of decorative applications. The
machined profile should not compromise the physical integrity of the board or induce cracking or
splitting of the product. Routed or grooved MiraTEC trim should not have any flat surfaces where
water can accumulate. Maintain an angle of at least 100 degrees from the vertical to provide posi
-
tive drainage and to prevent moisture from standing on the surface. Re-prime all machined areas
with a high quality exterior oil or acrylic latex primer formulated for composite wood. JELD-WEN,
inc. recommends using an oil-based primer.
STORAGE:
Cover when stored outside. Keep MiraTEC trim off the ground and dry. Excessive moisture
pickup from improper storage may affect the performance of MiraTEC trim. Do not stack
material in excess of 3 units high.
For job site storage, the material should be placed on stringers and covered, preferably on
concrete, asphalt, or a similar surface. For all other instances, a tarp should be placed over
the ground cover under the stringers, with the material still under cover.
TYPICAL TRIM USES:
MiraTEC trim can be used in a variety of applications as noted below.
IMPORTANT: Read and understand all application instructions before installing material. The statements expressed in this technical bulletin are the recommendations
for the application of the products as outlined and illustrated under normal conditions of installation. JELD-WEN, inc. is a manufacturer of building materials. It does not
practice architecture or engineering. The recommendations provided in this bulletin represent JELD-WEN, inc.’s best judgement based on its experience to date with
normal applications. These instructions supplement standard building practices and building code requirements; they are not to be deemed exclusive or exclusionary
of these practices and requirements. Unless prior approval is obtained in writing from the Product Performance Department of JELD-WEN, inc., PO Box 311, Towanda,
PA 18848, any deviation from these recommended procedures shall be at the risk of the installers.
These application instructions are the minimum requirements for the storage, application, and finishing of the trim products manufactured by JELD-WEN, inc. Where
building code requirements or standards are more restrictive, the applicable regulations must be followed. Consult your local representative or the Product Performance
Department for conditions not covered by this bulletin. All drawings are shown for illustration purposes only and are not to scale. Adequate design and bracing of the
walls, as well as compliance with these application instructions, are the responsibility of the architect, builder, applicator and painter.
5/16'' max depth
5/16'' max depth
5/16'' max depth
5/16'' max depth
5/16'' max depth
5/16'' max depth
Examples of machining
Ground tarp
Tarp to cover
MiraTEC
MiraTEC trim
1
2
3
4
5
6
7
6
8
9
10
1
2
3
4
5
6
7
8
9
10
Soffit
Frieze board
Fascia (use 5/8" trim for fascia)
Belly band or band board
Window trim
Corner board
Rake board or shingle mold
Architectural porch detail
Column wrap
Fluted door casing
Copyright © 2016 JELD-WEN, inc. Trademarks
shown are owned by JELD-WEN, inc. or
licensed by third parties. All rights reserved.
1.800.255.0785
miratectrim.com