Technical Specifications
ESR-3043
|
Most Widely Accepted and Trusted Page 2 of 3
4.0 DESIGN AND INSTALLATION
4.1 General:
MiraTEC
®
Treated Exterior Composite Trim is installed in
accordance with the manufacturer’s published installation
instructions and this report. The manufacturer’s published
installation instructions and this report must be strictly
adhered to, and a copy of the instructions must be
available at all times on the jobsite during installation. The
instructions within this report must govern if there are any
conflicts between the manufacturer’s published installation
instructions and this report.
4.2 Fasteners:
Fasteners used with MiraTEC
®
Treated Exterior Composite
Trim must be hot-dipped zinc-coated galvanized steel or
other corrosion-resistant fasteners in accordance with
Section 2304.10.5 of the IBC (Section 2304.9.5 of the 2012
and 2009 IBC) and Section R317.3 of the IRC. Nails are
6d, 8d or 15 gauge finish nails or headed nails long
enough to penetrate solid wood substrates a minimum
of 1
1
/
4
inches (32 mm). The fasteners are spaced at
16 inches (406 mm) and 24 inches (610 mm) on center.
When used for fascia applications, the fasteners are
spaced 24 inches (609.6 mm) on center.
4.3 Structural:
Maximum allowable transverse wind loads for MiraTEC
®
Treated Exterior Composite Trim with thicknesses of
nominal 1.0 inch [actual thickness 1.0 inch (25 mm)] and
nominal 1
1
/
4
inch [actual thickness 1.25 inches (32 mm)]
and widths of nominal 2-inch trim [actual size 2 inches
(51 mm)] up to nominal 16-inch trim [actual size
15.5 inches (394 mm)] are as noted in Table 1.
5.0 CONDITIONS OF USE
The MiraTEC
®
Treated Exterior Composite Trim described
in this report complies with, or is a suitable alternative to
what is specified in, those codes listed in Section 1.0 of
this report, subject to the following conditions:
5.1 This evaluation report and the manufacturer’s
published installation instructions, when required by
the code official, must be submitted at the time of
permit application.
5.2 The trim must be manufactured, identified and
installed in accordance with this report and the
Jeld-Wen, Inc., instructions.
5.3 The product must be limited to the following
construction types:
Nonload-bearing exterior trim on buildings of Type
VB construction under the IBC.
Combustible architectural trim on exterior walls of
buildings of Type I, II, III and IV construction under
the IBC. The buildings are limited to 40 feet
(12.2 m) in height above grade. The trim must be
backed by noncombustible material (Section
1405.5 of the IBC).
All buildings permitted under the IRC.
5.4 The product must be installed over solid backing
material, such as approved exterior sheathing
covered with an approved water-resistant barrier or
approved exterior wall covering.
5.5 MiraTEC
®
Treated Exterior Composite Trim is
manufactured at the Jeld-Wen, Inc., facility in
Towanda, Pennsylvania, under a quality-control
program with inspections by ICC-ES.
6.0 EVIDENCE SUBMITTED
Data in accordance with the ICC-ES Acceptance Criteria
for Wood-based Exterior Composite Trim Treated with Zinc
Borate (ZB) Preservative by a Non-pressure Process
(AC424), dated October 2010 (editorially revised January
2016).
7.0 IDENTIFICATION
Each package of MiraTEC
®
Treated Exterior Composite
Trim described in this report must be labeled with the
Jeld-Wen, Inc., name, address and telephone number; the
product trade name; and the evaluation report number
(ESR-3043).
8.0 OTHER CODES
In addition to the codes referenced in Section 1.0, the
products described in this report were evaluated for
compliance with the requirements of the following codes:
2006, 2003 and 2000 International Building Code
®
(IBC)
2006,
2003 and 2000 International Residential Code®
(IRC)
1997 Uniform Building Code™ (UBC)
BOCA® National Building Code/1999 (BNBC)
1999 Standard Building Code© (SBC)
1998 International One- and Two-Family Dwelling
Code
®
(IOTFDC)
The MiraTEC
®
Treated Exterior Composite Trim
described in this report complies with, or is a suitable
alternative to what is specified in, the codes listed above,
subject to the provisions of Sections 8.1 through 8.6.
8.1 Uses:
See Section 2.0.
8.2 Description:
See Section 3.0.
8.3 Installation:
See Section 4.0, except for the following modifications:
Fasteners used with MiraTEC
®
Treated Exterior
Composite Trim must be hot-dipped zinc-coated
galvanized steel or other corrosion-resistant fasteners in
accordance with Section 2304.9.5 of the 2006, 2003 and
2000 IBC; Section R319.3 of the 2006 and 2003 IRC;
Section R323.3 of the 2000 IRC; Section 2306.3 of the
SBC; Section 2311.3.3 of the BNBC; and Section 2304.3
of the UBC.
8.4 Conditions of Use:
See Section 5.0, except for the following modifications:
The product must be limited to the following construction
types:
Nonload-bearing exterior trim on buildings of
combustible nonfire-resistance-rated construction, Type
5B of the BNBC, Type VI unprotected of the SBC, and
Type VN of the UBC.
Combustible architectural trim on exterior walls of
buildings of Type 3 and 4 of the BNBC, Types I, II and
IV of the SBC and Types I, II, II, IV of the UBC.
Buildings are limited to 40 feet (12.2 m) in height above
grade [15 feet (4.6 m) for the UBC]. The trim must be
backed by noncombustible material.
All buildings permitted under the IOTFDC.
8.5 Evidence Submitted:
See Section 6.0.
8.6 Identification:
See Section 7.0.