Technical Specifications

ICC-ES Evaluation Report ESR-3043 FBC Supplement
Reissued August 2017
This report is subject to renewal August 2018.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council
®
DIVISION: 06 00 00WOOD, PLASTICS AND COMPOSITES
Section: 06 05 73.13Preservative Wood Treatment
DIVISION: 07 00 00THERMAL AND MOISTURE PROTECTION
Section: 07 46 23Wood Siding
REPORT HOLDER:
JELD-WEN, INC.
3737 LAKEPORT BOULEVARD
KLAMATH FALLS, OREGON 97601
(541) 882-3451
www.miratec@jeld-wen.com
www.miratectrim.com
EVALUATION SUBJECT:
MiraTEC
®
TREATED EXTERIOR COMPOSITE TRIM
REPORT PURPOSE AND SCOPE
Purpose:
The purpose of this evaluation report supplement is to indicate that MiraTEC
®
Treated Exterior Composite Trim, recognized
in ICC-ES master evaluation report ESR-3043, has also been evaluated for compliance with the codes noted below.
Applicable code editions:
2014 Florida Building CodeBuilding
2014 Florida Building CodeResidential
1.0 CONCLUSIONS
The MiraTEC
®
Treated Exterior Composite Trim, described in Sections 2.0 through 7.0 of the master evaluation report ESR-
3043, complies with the Florida Building CodeBuilding and Florida Building CodeResidential, provided the design and
installation are in accordance with the 2012 International Building Code
®
(IBC) provisions noted in the master report with the
following additional provisions:
1. Figure R301.2(4) of the Florida Building CodeResidential or Figure 1609 of the Florida Building CodeBuilding, as
applicable, must be used to establish required design wind speed.
2. Installation must comply with Section R318.7 of the Florida Building CodeResidential or Section 1403.8 of the Florida
Building CodeBuilding, as applicable.
3. Use of MiraTEC
®
Treated Exterior Composite Trim in soffit applications under the Florida Building CodeBuilding is
outside the scope of this supplemental report.
Use of the MiraTEC
®
Treated Exterior Composite Trim for compliance with the High-Velocity Hurricane Zone provisions of
the Florida Building CodeBuilding and Florida Building CodeResidential has not been evaluated, and is outside the
scope of this supplemental report.
For products falling under Florida Rule 9N-3, verification that the report holder’s quality assurance program is audited by a
quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the
responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by
the Commission).
This supplement expires concurrently with the master report, reissued August 2017.
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 1