Specifications
Table Of Contents
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
- Page 13
- Page 14
- Page 15
- Page 16
- Page 17
- Page 18
- Page 19
- Page 20
- Page 21
- Page 22
- Page 23
- Page 24
- Page 25
- Page 26
- Page 27
- Page 28
- Page 29
- Page 30
- Page 31
- Page 32
- Page 33
- Page 34
- Page 35
- Page 36
- Page 37
- Page 38
- Page 39
- Page 40
- Page 41
- Page 42
- Page 43
- Page 44
- Page 45
- Page 46
- Page 47
- Page 48
- Page 49
- Page 50
- Page 51
- Page 52
- Page 53
- Page 54
- Page 55
- Page 56
- Page 57
- Page 58
- Page 59
- Page 60
- Page 61
- Page 62
- Page 63
- Page 64
- Page 65
- Page 66
- Page 67

MIRCOM TECHNOLOGIES LIMITED, 9500 Series: No Subscriber Line Page 10
NON-SCROLLING DIRECTORY CONTROLLERS:
Model 9501A ± Main Controller.1000 residents capacity.
Model 9502A ± Add-on Controller for auxiliary entrance(s). 1000 residents capacity.
Model 9503 ± Multi-Building Guard House Controller. 1000 residents capacity.
Accessory:
PCB Assy.: MD-345 ± Auxiliary 6 relay board. This module is intended for use of Multiple Building
Application or for applications where relay contacts are required for activation of
peripherals. Please contact our Engineering Field Support Personnel for detailed
wiring scheme and information.
Note: Make sure to order the proper lobby panels meant for non-scrolling directory.
3. DECODER/RELAY CABINETS
Model 9508 ± Decoder/relay cabinet can hold up to eight (8) relay cards or ninety six (96)
telephone lines. Relay cards not included.
Model 9516 ± Decoder/relay cabinet can hold up to sixteen (16) relay cards or one
hundred ninety two (192) telephone lines. Relay cards not included.
Accessories:
Model 9512 ± Relay Card interfaces up to 12 telephone lines.
Model 9512E ± Elevator Recall Relay Card provides up to 12 relay contacts.
Model 9106 ± 6 Ft. Amphenol Cable. Standard for 9500 Series systems. Use this cable
for CA-71A or RJ-71C configured BIX Block.
Model 9106E ± 6 Ft. Amphenol Cable. Use this cable for interfacing the 9500 series systems to
existing RJ-71A configured BIX Block.
Model 9406 ± 6 Ft. Octopus Relay Cable. Use this cable for custom wiring the telephone's Tip
and Ring by using the standard CA-38A (RJ-38A) modular jacks.
4. SITE SELECTION
The Entry Panel should be installed as near as possible to the controlled entry point. Do not install the system in a
location where the LCD display is exposed to direct sunlight since it will reduce visibility.
5. POWER SUPPLY REQUIREMENTS
Select the appropriate power transformers required by your system configuration. Below are the transformer
models that are available:
.
Model PS-4 ± 16 VAC/ 40 VA, CSA approved Class 2 Power Transformer.
Model PS-3B ± 8 VAC/13 VA, 16 VAC/17 VA, 24 VAC/20 VA, CSA approved Class 2 Power
Transformer.
Model PS-13 ± 12VDC, 200mA.
6. WIRING REQUIREMENTS
Count the number of wires and identify the proper gauges that are required for your system configuration. For a
typical Single or Multiple entrance application, please refer to pages 5 and 6. For System Block Diagrams page 7.
For custom applications, we recommend consulting our Application Engineering personnel for evaluation.