User Manual

315 Daniel Zenker Drive
200 IST Center
Horseheads, NY 14845
USA
T +1.607.562.4369
+1.800.432.1478
F +1.607.562.4392
Station Road
Alton, Hampshire
GU34 2PZ, UK
T 01420.541600
F 01420.541700
Kaiser-Konrad-Str 93a
D 53225 Bonn
Deutschland
T 0228.625088
F 0228.626300
SPECIFICATIONS AND PERFORMANCE
PYROMETER SENSOR
Temperature Ranges /TR2: 1558°–3301°F (848°–1816°C)
/TR1: 1225°–2291°F (663°–1255°C)
Temperature Accuracy ±1.0% Full Scale
Measurement Technique Dual wavelength ratio pyrometry
Spectral Regions Narrow bands centered at 0.8 and
1.6 microns
Spot Size Approximately 1/24 of horizontal image width
Spatial Scan Resolution 47 horizontal x 35 vertical width of the image
Scan Rate Scan speed varies with size and number of
TMZ’s or via operator adjustment
LENS
Construction Air or water-cooled 304 stainless steel
outer shroud; sapphire window for max.
environmental protection
Type Straight view lens: /L30M
Length (L) 703mm (27.7”)
Type 45° offset lens: /OAL30W
Length (L) 694mm (27.3”)
For details on our full range of
Spyrometer lenses, please contact
your sales representative.
Field of View Wide: 75° H x 58° V
Medium: 50° H x 38° V
Narrow: 35° H x 26° V
Diameter /L: 1.5” (38mm); /OAL: 2.0” (51mm)
Cooling Requirements Instrument quality air*, 25-40 SCFM
(12–19 dm3/sec) @ 5-15 psig (34-103 kPa),
required for straight lens
Thermocouple /TJ: Type J thermocouple option;
/TK: Type K thermocouple option
*To ISO 8573-1, Class 1•7•2
CAMERA
Power 115-230 VAC, 50/60 Hz
Camera Detector Solid state color image sensor
System Resolution 300 lines minimum throughout the image
Video 1.0V p-p, 75ohm, CCTV signal
/VTN: NTSC or /VTP: PAL video timing
selected at time of order
Control Iris adjustment on rear of camera; remote iris
adjustment from the processor
Application Filter Filters are provided to match your process
and maximize performance. Contact your
Sales Representative
ENCLOSURE
Construction /CEI: Corrosion-resistant, insulated, air-
cooled, NEMA 4; /CEW: Corrosion-resistant,
water-cooled, NEMA 4
Cooling Type Vortex cabinet cooler, 25 SCFM @ 100 psi
(13 dm3/sec @ 690 kPa); instrument-quality
air required or water cooled option available
Ambient Environment Max. 140°F (60°C) with negligible radiant heat
load. Water cooled option available to handle
high radiant heat environment
MECHANICAL
Video Output Jack Female PL-259 “UHF” type
Power Input Jack Removable waterproof miniplug (JOY type
TP, female 3-conductor; mating power
cord provided)
Enclosure Cooling Input 1/4” brass quick-disconnect nipple; mating
coupler (Snaptite BVHC4-4F) provided
Lens Cooling Input 1/2” brass quick-disconnect nipple; mating
coupler (Snaptite BVHC8-8F) provided
Weight 30 pounds (14kg) for standard air-cooled
conguration (lens and camera)
© Copyright 2008. All rights reserved for trademark and registered trademark
information.
The above specications may vary according to system conguration.
Mirion Technologies Incorporated reserves the right to amend or change the
information on this sheet without prior warning.
12/08