Owner manual

Health Physics
Division
Since norms, specications and designs are subject to occasional change, please ask for conrmation of the information given in this publication.
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
Lieu-Dit Calès,
Route d’Eyguières
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technologies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
Mirion Technologies Shanghai Branch
Room 801, 78 Jiangchang
San Lu, Zhabei District
Shanghai 200436
China
T +86 21 6180 6920
F +86 21 6180 6924
SPIR-IDENT VEHICLE - GN
Detection and Identication - Risks Prevention
www.mirion.com
148998EN-B
DESCRIPTION
One to four detection pillars including each a 2 or 4 liter
NaI(Tl) gamma detector and one or two moderated He3
or BF3 neutron detectors
Three sided lead shielding
Each gamma detector is associated with a fast digital
spectrometer
Standard or Panel PC with SPIR-IDENT Server software,
Portal and Expert mode interface
Includes SIA identication algorithm designed for
challenging Homeland Security issues
Remote cameras control option
With or without occupancy signal
FUNCTIONS
0.5 sec continuous elementary spectra acquisition and
sourceless stabilization
Count rate and dose rate calculation, alert criteria
monitoring
Real-time identication per channel and group of
channels
Spectra accumulation during occupancy for preset time
with resume capability
Automated report per measurement including pictures
(user comments can be included)
Sliding spectra analysis between occupancies to
monitor background and for vehicle prole analysis
PERFORMANCES
Isotope list:
according to ANSI N42-38, IEC and IAEA standards
Industrial, SNM, Medical and NORM radionuclides
Gamma detection and identification capability:
according to conguration, designed to exceed ANSI
N42-38 (vehicle, static mode)
surpassing performance: identies 10 μCi 137Cs
shielded with
3 cm (1.1 in) iron (ANSI requirement: 85 μCi)
includes special processing for shielded or masked
isotopes for example SNM masked by medicals or
NORMs
Neutron detection capability:
according to conguration, designed to exceed ANSI
N42-38 / IAEA recommendation
COMMUNICATION
Ethernet (network) connectivity
DIMENSIONS (PER PILLAR)
Body: 148 cm x 50,2 cm x 22,2 cm (57 in x 19,73 in x
8,74 in)
Base: Ø 32 cm (12.6 in)
Weight: 62 kg (137lb)
Expert mode graphical user interface
Portal interface detailed results
Vehicle Portal graphical user interface