8.0 PRODUCT ELECTRICAL SPECIFICATIONS
PV Modules have been certified for a maximum static load on the back of the module of up to 2400 Pa (i.e.
wind load) and a maximum static load on the front of the module of up to either 2400 Pa or 5400 Pa (i.e. wind
and snow load). The performance of solar modules is defined on the uniform standard test conditions. These
conditions define performance at an incident sunlight of 1000 W/m
2
, a cell temperature of 25
o
C (77
o
F) and an
AM of 1.5 (AM = Air Mass). The air mass determines the radiation impact and the spectral combination of the
light arriving on the earth’s surface. Modules have been evaluated by UL for a maximum positive test load of
113 lbs/ft
2
and negative test loading of 50 lbs/ft
2
.
Rated electrical characteristics (excluding the rated maximum power) are within 10 percent of measured values
at Standard Test Conditions of: 1000 W/m2, 25°C cell temperature and solar spectral irradiance per ASTM E
892. Only rated maximum power is within -0/3%.
Table 1: Electrical Ratings of MSE 350 PERC Module Series
Model P PERC
Crystalline
Open Circuit
Voltage at
STC, (V dc)
Rated Voltage
at STC, (V dc)
Maximum
System
Voltage, (V dc)
Rated Current
at STC, (A dc)
Short-Circuit
Current at STC,
(A dc)
Rated Maximum
Power at STC,
(Watts)
MSE345SQ4S/
MSE345SQ6S
46.98 38.43 1500 9.04 9.70 345
MSE350SQ4S/
MSE350SQ6S
47.38 38.68 1500 9.11 9.73 350
MSE355SQ4S/
MSE355SQ6S
47.68 38.98 1500 9.19 9.76 355
MSE360SQ4S/
MSE360SQ6S
48.08 38.28 1500 9.28 9.79 360
MSE365SQ4S/
MSE365SQ6S
48.12 39.32 1500 9.32 9.81 365
Table 2: Electrical Ratings of MSE 295 PERC 60 Module Series
Model P PERC
Crystalline
Open Circuit
Voltage at
STC, (V dc)
Rated Voltage
at STC, (V dc)
Maximum
System
Voltage, (V dc)
Rated Current
at STC, (A dc)
Short-Circuit
Current at STC,
(A dc)
Rated Maximum
Power at STC,
(Watts)
MSE280SQ5T
39.31
32.17
1000
8.79
9.31
280
MSE285SQ5T 39.56 32.36 1000 8.87 3.37 285
MSE290SQ5T 39.81 32.54 1000 8.95 9.44 290
MSE295SQ5T
40.11
32.72
1000
9.03
9.52
295
MSE300SQ5T 40.18 32.80 1000 9.17 9.61 300