Table 3: Electrical Ratings of MSE Mono 72 Module Series
Model Mono
Crystalline
Open Circuit
Voltage at
STC, (V dc)
Rated Voltage
at STC, (V dc)
Maximum
System
Voltage, (V dc)
Rated Current
at STC, (A dc)
Short-Circuit
Current at STC,
(A dc)
Rated Maximum
Power at STC,
(Watts)
MSE320SO4J/
MSE320SO6J
45.68
37.65
1500
8.51
8.97
320
MSE325SO4J/
MSE325SO6J
45.79
37.72
1500
8.62
9.08
325
MSE330SO4J/
MSE330SO6J
46.12
37.85
1500
8.72
9.23
330
MSE335SO4J/
MSE335SO6J
46.14
37.89
1500
8.87
9.38
335
MSE340SO4J/
MSE340SO6J
46.35
38.02
1500
8.95
9.49
340
MSE345SO4J/
MSE345SO6J
46.52
38.14
1500
9.05
9.52
345
MSE350SO4J/
MSE350SO6J
46.57
38.31
1500
9.14
9.59
350
Table 4: Electrical Ratings of MSE Mono 60 Module Series
Model Mono
Crystalline
Open Circuit
Voltage at
STC, (V dc)
Rated Voltage
at STC, (V dc)
Maximum
System
Voltage, (V dc)
Rated Current
at STC, (A dc)
Short-Circuit
Current at STC,
(A dc)
Rated Maximum
Power at STC,
(Watts)
MSE260SO5T 37.89 30.82 1000 8.44 8.90 260
MSE265SO5T 38.07 31.14 1000 8.53 8.99 265
MSE270SO5T 38.21 31.28 1000 8.64 9.09 270
MSE275SO5T 38.45 31.55 1000 8.72 9.17 275
MSE280SO5T 38.60 31.87 1000 8.79 9.27 280
MSE285SO5T 38.82 32.11 1000 8.88 9.36 285
MSE290SO5T 39.21 32.38 1000 8.96 9.38 290
9.0 MECHANICAL INSTALLATION
The module is considered to be in compliance with IEC 61730 and UL 1703 only when the module is mounted
in the manner specified by the mounting instructions below. We recommend using the following orientation
to install the module. Maximum number of modules connected in series /parallel for MSE 350 PERC is 24/1
and maximum number of modules connected in series /parallel for MSE 295 PERC 60 is 19/1.