SDS
SAFETY DATA SHEET
A00364 MST SOLVENT DGRSR 20NET14
Version 2.0
Revision Date 10/01/2017
Print Date 12/17/2020
4 / 11
for firefighters
necessary.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal precautions,
protective equipment and
emergency procedures
:
Use personal protective equipment.
Ensure adequate ventilation.
Remove all sources of ignition.
Evacuate personnel to safe areas.
Beware of vapours accumulating to form explosive
concentrations. Vapours can accumulate in low areas.
Environmental precautions
:
Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform
respective authorities.
Methods and materials for
containment and cleaning up
:
Soak up with inert absorbent material (e.g. sand, silica gel,
acid binder, universal binder, sawdust).
SECTION 7. HANDLING AND STORAGE
Advice on safe handling
:
Do not breathe vapours/dust.
Avoid exposure - obtain special instructions before use.
Avoid contact with skin and eyes.
For personal protection see section 8.
Smoking, eating and drinking should be prohibited in the
application area.
Take precautionary measures against static discharges.
Provide sufficient air exchange and/or exhaust in work rooms.
Dispose of rinse water in accordance with local and national
regulations.
Persons susceptible to skin sensitisation problems or asthma,
allergies, chronic or recurrent respiratory disease should not
be employed in any process in which this mixture is being
used.
Always replace cap after use.
Conditions for safe storage
:
BEWARE: Aerosol is pressurized. Keep away from direct sun
exposure and temperatures over 50 °C. Do not open by force
or throw into fire even after use. Do not spray on flames or
red-hot objects.
No smoking.
Observe label precautions.
Electrical installations / working materials must comply with
the technological safety standards.
Materials to avoid
:
Store and keep away from, oxidizing agents and acids.
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters