Technical Specifications
150
© 2015 MiTek. All rights reserved.
EWP Hangers
BPH / HBPH Top Mount Hangers
These hangers are used to support LVL, LSL, and PSL beams and
headers in medium-to-heavy load conditions.
Materials: BPH – 12 gauge; HBPH – 10 gauge
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• Refer to the top mount chart for applications requiring web stiffeners.
• Requirements for web stiffener from the I-Joist manufacturer should be
followed, even if web stiffeners are not required in USP literature.
• For welded installations, see page 232.
Typical BPH
installation
Typical HBPH
installation
BPH HBPH
Nailer Options
– chart represents maximum allowable loads for hangers used on wood
nailers. Reference page 140.
Specialty Options Chart
– refer to Specialty Options pages 228 and 230 for additional details
Qty Type Qty Type 100% 100%
2X 6 10d x 1-1/2 4 10d x 1-1/2 2080 230 1790 200
3X 8 16d x 2-1/2 4 10d x 1-1/2 2360 535 2030 460
(2) 2X 8 10d 4 10d x 1-1/2 2310 535 1985 460
4X 8 16d 4 10d x 1-1/2 2245 535 1930 460
2X 6 10d x 1-1/2 4 10d x 1-1/2 2080 230 1790 200
3X 8 16d x 2-1/2 4 10d x 1-1/2 2360 535 2030 460
(2) 2X 8 10d 4 10d x 1-1/2 2310 535 1985 460
4X 8 16d 4 10d x 1-1/2 2245 535 1930 460
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) Listed loads shall not be increased.
3)
NAILS:
10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long,
16d nails are 0.162" dia. x 3-1/2" long, 16d x 2-1/2 nails are 0.162" dia. x 2-1/2" long.
New products or updated product information are designated in
blue font
.
HBPH
BPH
Uplift
1
160%
Uplift
1
160%
DF/SP
Allowable Loads (Lbs.)
2
S-P-F
Allowable Loads (Lbs.)
2
USP
Series
Nailer
Size
Fastener Schedule
3
Header Joist
Option
Skewed
1,3
Sloped Seat
2,3
Sloped / Skewed
1,2,3
Sloped Top Flange
4
Range 1˚ to 50˚ 1˚ to 45˚ See Sloped Seat and Skewed 0˚ to 45˚
1
)
Skewed han
g
ers with skews
g
reater than 15° ma
y
have all
j
oist nailin
g
on outside flan
g
e.
2
)
Slo
p
ed or slo
p
ed / skewed han
g
ers with slo
p
es
g
reater than 15° ma
y
have additional
j
oist nails.
3
)
For skewed han
g
ers
,
the re
q
uired cut t
yp
e
(
s
q
uare or bevel
)
of
j
oist member ma
y
var
y
based on skew an
g
le
and width of han
g
er. Some s
q
uare cut han
g
ers will re
q
uire custom
p
ricin
g
due to welded back
p
late.
4
)
Slo
p
ed to
p
flan
g
es with slo
p
es
g
reater than 15° ma
y
have additional header nails.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
Reduce allowable
table loads using
straight-line interpolation
Add SK , angle required,
right (R) or left (L) , and
square cut
(SQ)
or bevel cut
(BV)
to product number.
Example: BPH3595_SK45R_SQ
Add SL, slope required,
and up (U) or down (D),
to product number.
Example:
BPH3595_SL30D
See Sloped Seat and Skewed.
Example:
BPH3595_SK45R_SQ_SL30D
Add SF, angle required
and right (R) or left (L),
to product number.
Example:
BPH3595_SF30L
Allowable
Loads
Ordering
100% of table load 100% of table load 100% of table load
EWP Hangers
H
H
W
W
D
D
TF
TF