Technical Specifications

67
Caps & Bases
© 2015 MiTek. All rights reserved.
EBG / EPB / EPBH Elevated Post Bases
These post bases allow installers to pre-align posts and
preset post heights above concrete oors or footings. By
eliminating post-to-concrete contact, moisture damage
is reduced. Elevated post bases are ideal for building
carports, decks or porches. All series feature convenient
nail fastening to post.
Materials: See chart
Finish: EPB – USP primer;
EBG44-TZ – G-185 galvanizing;
EPBH – Hot-dip galvaized
Options: See chart for Corrosion Finish Options
Codes: See page 11 for Code Reference Chart
IRC R317.1.4, IBC 2304.11.2.7,IRC R407.3, IBC 2304.9.7.
Installation:
• Use all specied fasteners. See Product Notes, page 17.
Not recommended for fence post or other xed
post applications. These anchors are not designed
to resist overturning (moment) loads.
Maintain 3" minimum edge distance between embedded
tube and edge of concrete.
Ref. No. W L H1 H2 Qty Nail
EBG44-TZ EPB44A 14 16 3-9/16 2-3/4 2-3/8 7-1/2 8
16d
HDG
2155 1085 1505 1255 1510 835 1055 880
EPB4408
EPB44,
EPB44-12
12 -- 3-9/16 3 3 8 8 16d 3045 905 1505 1255 2675 635 1055 880
EPBH44 RCPS3.5HDG 12 -- 3-1/2 3-3/8 2-3/4 7 4
16d
HDG
4615 990 990 975 3830 990 785 785 130
4 x 6 EPB4608
EPB46,
EPB46-12
12 -- 3-9/16 5 3 8 12 16d 3045 905 1505 1255 2675 635 1055 880 110
4 x 6
Rough
EPBH46R RCPS46HDG 12 -- 4-1/8 5-3/8 3 130 4
16d
HDG
4615 990 990 975 3830 990 785 785 130
EPB6608
EPB66,
EPB66-12
12 -- 5-9/16 5 3-3/16 8 12 16d 3825 905 1505 1255 2675 635 1055 880 110
EPBH66 RCPS5.5HDG 12 -- 5-1/2 5-3/8 3 7 4
16d
HDG
4615 990 990 975 3830 990 785 785
6 x 6
Rough
EPBH66R RCPS6HDG 12 -- 6-1/8 5-3/8 3 7 4
16d
HDG
4615 990 990 975 3830 990 785 785
EBG44-TZ EPB44A 14 16 3-9/16 2-3/4 2-3/8 7-1/2 8
16d
HDG
1845 1020 1290 1075 1290 715 900 750
EPB4408
EPB44,
EPB44-12
12 -- 3-9/16 3 3 8 8 16d 3045 775 1290 1075 2295 540 900 750
EPBH44 RCPS3.5HDG 12 -- 3-1/2 3-3/8 2-3/4 7 4
16d
HDG
4615 990 965 965 3285 990 675 675 130
4 x 6 EPB4608
EPB46,
EPB46-12
12 -- 3-9/16 5 3 8 12 16d 3045 775 1290 1075 2295 540 900 750 110
4 x 6
Rough
EPBH46R RCPS46HDG 12 -- 4-1/8 5-3/8 3 7 4
16d
HDG
4615 990 965 965 3285 990 675 675 130
EPB6608
EPB66,
EPB66-12
12 -- 5-9/16 5 3-3/16 8 12 16d 3275 775 1290 1075 2295 540 900 750 110
EPBH66 RCPS5.5HDG 12 -- 5-1/2 5-3/8 3 7 4
16d
HDG
4615 990 965 965 3285 990 675 675
6 x 6
Rough
EPBH66R RCPS6HDG 12 -- 6-1/8 5-3/8 3 7 4
16d
HDG
4615 990 965 965 3285 990 675 675
1
)
Lateral loads
(
F1 and F2
)
are for conditions where
p
i
p
e extends no more than 1" above the concrete surface.
2
)
U
p
lift Loads have been increased 60% for wind and seismic loads; no further increase shall be
p
ermitted.
3
)
Minimum nail embedment shall be 1-5/8" for 16d nails.
4
)
Concrete com
p
ressive stren
g
th shall be 2,000
p
si or
g
reater at 28 da
y
s.
5
)
NAILS: 16d nails are 0.162" dia. x 3-1/2" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
6 x 6
4 x 4
6 x 6
4 x 4
SDC C-F
110
110
130
130
F2
1
160%
Download
100%
Uplift
2
160%
F1
1
160%
F2
1
160%Tube
SDC A & B
Corrosion
Finish
Post
Size
Code
Ref.
USP
Stock No.
DF/SP Allowable Loads (Lbs.)
4
Dimensions (in)
Fastener
Schedule
3,5
Uncracked Concrete
Base
Steel
Gauge
Cracked Concrete
Download
100%
Uplift
2
160%
F1
1
160%
EPBH
EBG44-TZ
Typical EPBH
installation
Typical EBG44-TZ
installation
EPB
Typical EPB
installation
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
W
H1
L
H2
W
H1
L
H2
F2
F1
Uplift
Bearing
1" max.
elevation
Caps & Bases
W
H1
L
H2