Technical Specifications
209
Plated Truss
© 2015 MiTek. All rights reserved.
FTC / FTCF Floor Truss Clips
FTC clips slide easily onto the top or bottom chord and provides
a guide to help position and support the second truss during assembly.
FTCF clips easily install after the trusses are installed.
Materials: 18 gauge
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Patents: #5,653,079
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• The truss designer must determine the number of clips and spacing
between units according to concentrated load conditions and
uniform loading requirements.
Concentrated Load Spacing Tips:
Divide half of the concentrated load by the clip capacity to nd
the number of clips required.
Example:
Concentrated (point) load = 3000 lbs, FTC1 capacity (DF/SP) = 865 lbs
= 1.73 = 2 clips
Place 2 clips near concentrated load.
Uniform Load Spacing Tips:
Divide the clip capacity by half the required load per lineal foot.
Example:
Uniform (distributed) load = 500 lbs/ft, FTC1 capacity (DF/SP) = 865 lbs
= 3.46' spacing
Space clips at 3'4" along length of truss.
1⁄2 (3000 lbs)
865 lbs
865 lbs
1⁄2 (500 lbs)
FTC
Typical FTC installation
Typical FTC
2-ply metal web truss
installation
Typical FTC2F
retrot installation
Ref. No. W1 W2 H Qty Type
3 x 2 FTC32 -- -- 18 2-1/16 2-1/2 1-1/2 10 10d x 1-1/2 680 590
FTC1 -- -- 18 3-1/2 3-1/16 1-1/2 10 10d 865 750
FTC1F -- -- 18 3-1/16 -- -- 4-3/8 10 10d 865 750
FTC2 -- -- 18 3-1/2 3-1/16 3 10 10d 865 750
FTC2F -- -- 18 3-1/16 -- -- 4-3/8 10 10d 865 750
1) Transfer loads are for 100% floor load, and shall not be increased for short term load duration.
2) Minimum nail penetration shall be 1-1/2" for 10d nails.
3) Truss designer shall determine the number of clips for concentrated loads and the spacing for uniform loads.
4)
NAILS:
10d x 1-1/2" nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long.
New products or updated product information are designated in
blue font
.
Code
Ref.
4 x 2
(2) 4 x 2
USP
Stock No.
Steel
Gauge
10,
R8,
F5
DF/SP
Maximum
Transfer
Loads
1,3
S-P-F
Maximum
Transfer
Loads
1,3
Truss Size
Fastener
Schedule
2,4
Dimensions (in)
Step 1 Step 2
Plated Truss
4-3/8"
W2
W1
1-1/8"
2"
H
FTCF
FTC1F= 6-1/16"
FTC2F=7-5/8"
4-3/8"
3-1/16"
2-1/16"