Technical Specifications

181
Truss & Rafter
© 2015 MiTek. All rights reserved.
RT16M Hurricane Retrot Connector
Designed as a retrot connector for trusses installed on top
plates. Can also be used as a holdown for a roof or oor system.
Materials: 18 gauge
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
Tapcon
®
Concrete Screws are not supplied with
RT16M connector.
Install Tapcon
®
Concrete Screws in lower two holes for Single
Top Plate or Conventional Raised Foundation or Modular Home
Installations.
Moisture barrier may be required.
Typical RT16M
top plate installation
RT16M
Ref. No. Qty Type Qty Type Qty Type F1 F2 F3 F1 F2 F3
9 10d x 1-1/2 -- -- -- -- 4 1/4" x 1-3/4" Tapcon 1395 630 480 115 1395 630 480 115
9 10d x 1-1/2 4 16d 2 1/4" x 1-3/4" Tapcon 1360 -- -- -- -- -- -- 1360 -- -- -- -- -- --
1
)
Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
Install with 1/4" x 1-3/4" Ta
p
con® Concrete Screws in accordance to manufacturer's installation s
p
ecifications.
3
)
Fasteners to be installed to full
y
g
routed and reinforced concrete masonr
y
.
4
)
Concrete com
p
ressive stren
g
th shall be 2500
p
si or
g
reater at 28 da
y
s.
5
)
NAILS: 10d x 1-1/2" nails are 0.148" dia. x 1-1/2" lon
g
, 16d nails are 0.162" dia. x 3-1/2" lon
g
.
HM9KT RT16M
Truss/Rafter
5
Top Plate
5
USP
Stock No.
18
Steel
Gauge
Fastener Schedule
Code
Ref.
F19
CMU/Concrete
2,3,4
Lateral 160%
Uplift
160%
DF/SP
Allowable Loads (Lbs.)
1
Uplift
160%
Lateral 160%
S-P-F
Allowable Loads (Lbs.)
1
Typical HGA10 installation HGA10
Designed for attaching gable end trusses to wood top plates and
masonry walls.
Versatile wood-to-wood connector that satises high wind and
seismic loading requirements.
Materials: 14 gauge
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
HGA10 – Install with USP’s WS3 Wood Screws into top plate,
and WS15 Wood Screws into the truss.
• WS Wood Screws are included with HGA10 angles.
Moisture barrier may be required.
Uplift
Ref. No. Qty Type Qty Type 160% F1 F2 F3
HGA10KT HGA10KT 14 4 WS15 4 WS3 1285 1320 1565 835
10, R8, F5
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) WS15 Wood Screws are 1/4" x 1-1/2" long and WS3 Wood Screws are 1/4" x 3" long.
blue font
.
Code
Ref.
Lateral 160%
DF/SP Allowable Loads (Lbs.)
1
USP
Stock No.
Steel
Gauge
Fastener Schedule
2
Rafter/Truss Plate
HGA Hurricane Gusset Angles
F1
5"
1-9/16"
F2
F3
Uplift
8-15/16"
3-1/2"
Uplift
F1
F2
3-1/2"
Embossed
gussets
improve
lateral load
resistance
F3
3"
2"
Truss & Rafter