Technical Specifications
52
Holdowns
© 2015 MiTek. All rights reserved.
HTT Tension Ties
Secures multi-ply studs or posts to mudsills or foundation. Nail
fastening makes for a convenient connection to studs or posts in
cramped retrot installations.
Materials: See chart
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Key Chart
Installation:
• Use all specied fasteners to attach the strap portion of the
connector to the side of stud, post, joist, purlin, or beam. Secure
the base to the concrete or masonry wall with specied anchor
bolt. A design professional shall specify the type, length, and
embedment of the anchor bolt.
• HTT45 Max – Fill all round and diamond nail holes.
• Washers are not required on transfer plates that t over the
anchor bolt.
• Tighten anchor bolt nuts nger tight snug to base plus, 1/3 to 1/2
additional turns with a wrench. To prevent loosening of the anchor
nut during critical loading, use a locking nut or tighten a second nut
over the rst to lock nuts in place.
• HTT4 & HTT5 — eld bending is not required provided minimum
fastener edge distance of 3/8" is maintained.
• LL930 LumberLok screws are included with HTT5KT.
HTT16
HTT4
(HTT5 similar)
Typical HTT4
installation
(HTT5 Similar)
HTT45
Typical HTT45
installation
Typical HTT16
installation
Ref. No. Strap Plate W L D CL Qty Dia. Qty Type 160% Δ (in)
4,5
10d x 1-1/2 2715 0.095
10d 3295 0.098
16d x 2-1/2 4465 0.143
10d x 1-1/2 3225 0.088
10d 4745 0.122
16d x 2-1/2 5430 0.141
HTT5KT
6
HTT5KT 12 -- -- 3 13-15/16 2-3/4 1-3/8 1-3/4 1 5/8 28 LL930 6000 0.079 130
HTT16 -- -- 10 -- -- 2-1/2 15-5/8 2 1-3/8 1-3/4 1 5/8 18 10d 3610 1.142
10d 0.095
16d x 2-1/2 0.108
10d 0.138
16d x 2-1/2 0.101
1
)
Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
16d sinkers ma
y
be substituted for the s
p
ecified 10d common nails with no load reduction.
3
)
The desi
g
ner must s
p
ecif
y
anchor bolt t
yp
e, len
g
th and embedment de
p
th.
4
)
Deflections are derived from static, monotonic load tests of devices connected to DF wood members with s
p
ecified fasteners.
5
)
HTT holdowns raised off of the sill
p
late ma
y
have hi
g
her deflection values.
6
)
HTT5KT is sold as a kit and includes
(
1
)
HTT5 and
(
28
)
LL930 screws.
7
)
LL930 LumberLok Screws are #9 x 2-7/8" lon
g
.
8
)
NAILS: 10d x 1-1/2" nails are 0.148" dia. x 1-1/2" lon
g
, 10d nails are 0.148" dia. x 3" lon
g
, 16d x 2-1/2" nails are 0.162" dia. x 2-1/2" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
USP
Stock No.
12 HTT4 -- --
HTT5 -- --
HTT45 (Min)
HTT45 (Max) 5005
Code
Ref.
5/8
5/81-3/8 1
1-3/4
1-3/4
1-3/82-3/4
2-3/4
1-3/810
12
Nail
Spacing
Dimensions (in)
HTT4,
HTT5
3 13-15/16
10-7/16
1-3/4 -- -- 2-1/2 16 2
3
Steel
Gauge
-- --
-- --
5/8
4160
30,
F31,
R16
F14
Anchor
Bolt
3
Strap
2,3,7,8
20
28
18
26
DF/SP
Allowable Tension
Loads (Lbs.)
1
Fastener Schedule
1
1
W
W
W
L
L
D
Standard round
nail holes for
minimum nailing
Additional
diamond holes
for maximum
nailing
D
D
CL
CL
CL
L
Holdowns