Technical Specifications
101
Angles & Straps
© 2015 MiTek. All rights reserved.
Ref. No. W L L1 L2 Qty Type 160% 160%
12 10d x 1-1/2
12 10d
12 10d x 1-1/2
12 10d
12 10d x 1-1/2
12 10d
12 10d x 1-1/2
12 10d
KTS9 TS9 16 1-1/4 9 -- -- -- -- 8 16d 785 660
KTS12 TS12 16 1-1/4 11-1/2 -- -- -- -- 10 16d 1065 895
14 10d x 1-1/2
14 10d
14 10d x 1-1/2
14 10d
KTS17 TS18 16 1-1/4 17-1/2 -- -- -- -- 14 16d 1100 925 130
14 10d x 1-1/2
14 10d
16 8d
16 8d x1-1/2
14 10d x 1-1/2
14 10d
KTS24 TS22 16 1-1/4 21-3/4 -- -- -- -- 18 16d
1650 1385
130
14 10d x 1-1/2
14 10d
14 10d x 1-1/2
14 10d
14 10d x 1-1/2
14 10d
14 10d x 1-1/2
14 10d
16 10d x 1-1/2
16 10d
24 10d x 1-1/2
20 10d
24 10d x 1-1/2
20 10d
24 10d x 1-1/2
20 10d
24 10d x 1-1/2
20 10d
24 10d x 1-1/2
20 10d
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) Minimum nail embedment shall be 1-5/16" for 8d nails and 1-1/2" for 10d nails.
3) 16d sinker nails may be substituted for 10d common nails with no reduction in load.
4) For 1-1/2" lumber, use 0.84 of table load for 10d nails and 0.77 for 16d nails.
5) Fasteners shall be distributed equally on each end of the connection.
6) C after the model number designates center twist as in MTW30C.
7) LFTA6: F1 is 700 lbs and F2 is 90 lbs. To achieve F1 lateral loads, three nails must be installed on each side on the strap
located closest to the bend line. Lateral F1 and F2 load directions do not apply to roof truss-to-top plate installations.
8)
NAILS:
8d x 1-1/2" nails are 0.131" dia. x 1-1/2" long, 8d nails are 0.131" dia. x 2-1/2" long, 10d x 1-1/2" nails are
0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, 16d nails are 0.162" dia. x 3-1/2" long.
New products or updated product information are designated in
blue font
.
7-1/2
6-1/2
5-1/8
8-1/2 8-1/2
USP
Stock No.
6
Steel
Gauge
1-1/4
1-1/4
1-1/4
4-1/2
6-1/2
8-1/2
MTS12
MTW16 MTS16
MTW18 MTS18
7-1/2 LTW18
LTS20
MTW12
1-1/4
1-1/4
Dimensions (in)
Fastener
Schedule
2,3,4,5,8
LTW16 LTS16 1-1/4
650
650
LTW12 4-1/2 LTS12 18
18
4-1/2
6-1/2
12
16
DF/SP
Allowable Uplift
Loads (Lbs.)
1
1-1/4
HTW30C HTS30C
18
18
16
16
16
HTW28 -- --
HTW30 HTS30
HTW20 HTS20
HTW24 HTS24
MTW30C MTS30C
MTW20 MTS20
14
14
14
LFTA6
7
14
14
14
16
16
16
16
24
28
LTW20
1-1/4
1-1/4
4-1/2
8-1/2
7-1/8
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
30
16
20
24
20
30
12-7/16
HTW16
20
28
7-1/2
7-1/8
9-1/8 9-1/8
12-1/812-1/8
7
11-1/8 11-1/8
17-1/430
30
13-7/16
5-1/8
18
HTS16
775
775
775
775
16 2-1/4 19-1/8 8-3/8 6-1/2
6-1/2
1195
1195
1195
1195
18-9/16
10-7/16
12-7/16
10-7/16
7-1/2
LTS18 18
12
16
MTW30 MTS30
MTW24C MTS24C
MTW28C -- --
13-7/16
8-5/16
1210
1195
1195
1195
1195
16
H6
1530
1260
1530
1530 1285
1285
1060
1285
1530
1530
Corrosion
Finish
14,
R9,
F7
14,
R9,
F7
14,
R9,
F7
14,
R9,
F7
Code
Ref.
1285
1285
1005
1005
1005
1005
1005
650
650
1015
1005
1005
1005
130
S-P-F
Allowable Uplift
Loads (Lbs.)
1
1) Allowable loads have been in-
creased 60% for wind or seismic
loads; no further increase shall
be permitted.
2) Minimum nail embedment shall
be 1-5/16" for 8d nails and
1-1/2" for 10d nails.
3) 16d sinker nails may be
substituted for 10d common
nails with no reduction in load.
4) For 1-1/2" lumber, use 0.84 of
table load for 10d nails and 0.77
for 16d nails.
5) Fasteners shall be distributed
equally on each end of the
connection.
6) C after the model number
designates center twist as in
MTW30C.
7) LFTA6: F1 is 700 lbs and F2
is 90 lbs. To achieve F1 lateral
loads, three nails must be in-
stalled on each side on the strap
located closest to the bend line.
Lateral F1 and F2 load directions
do not apply to roof truss-to-top
plate installations.
8) NAILS: 8d x 1-1/2" nails are
0.131" dia. x 1-1/2" long, 8d
nails are 0.131" dia. x 2-1/2"
long, 10d x 1-1/2" nails are
0.148" dia. x 1-1/2" long, 10d
nails are 0.148" dia. x 3" long,
16d nails are 0.162" dia. x
3-1/2" long.
New products or updated product
information are designated in
blue font.
LTW18/MTW18
other models similar
Typical MTW30
installation
KTS
MTW30/
HTW30
MTW30C
HTW / KTS / LFTA6 / LTW / MTW Twist Straps
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Typical MTW20
I-joist rafter
installation
L1
L2
L
1-1/4"
1-1/4"
1-1/4"
1" Typ.
L2
L1
L
Angles & Straps