Technical Specifications

128
Hangers
© 2015 MiTek. All rights reserved.
KF / PHG Panel Hangers
Materials: 20 gauge
Finish: G90 galvanizing
Options: See chart for Corrosion Finish Options
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• Diamond holes allow optional header nailing.
Joist nails must be driven at a 30° to 45° angle through the purlin
into the header to achieve listed loads. Standard length “double
shear” nails must be used to achieve listed load values.
16d sinkers (0.148" dia. x 3-1/4") may be used where 10d
commons are specied with no load reduction.
Ref. No. W H D
5
Qty
Type
Qty
Type
125%
2 x 4 PHG24 HF24N 18 1-9/16 3-1/2 1-3/16 1-1/16 2 8d -- -- -- -- 580
2 x 6 PHG26 HF26N 18 1-9/16 5-3/8 1 1-1/16 2 10d -- -- -- -- 650
3 x 4 PHG34 HF34N 18 2-9/16 3-1/2 1 1-1/8 2 10d -- -- -- -- 650
3 x 6 PHG36 HF36N 18 2-9/16 5-3/8 1 1-1/8 2 10d -- -- -- -- 650
(2) 2 x 4 PHG24-2 F24-2 18 3-1/8 3-1/2 1 1-1/8 2 10d -- -- -- -- 650
(2) 2 x 6 PHG26-2 F26-2 18 3-1/8 5-3/8 1 1-1/8 2 10d -- -- -- -- 650
4 x 4 KF44 F44 18 3-9/16 3-3/8 1 1-1/8 2 10d 1 10d x 1-1/2 695
4 x 6 KF46 F46 18 3-9/16 5-3/8 1 1-1/8 2 10d 1 10d x 1-1/2 810
1) Loads listed are per side.
2) Minimum nail embedment shall be 1-5/16" for 8d nails and 1-1/2"for 10d nails.
3)
NAILS:
8d nails are 0.131"dia. x 2-1/2" long, 10d x 1-1/2 nails are 0.148"dia. x 1-1/2" long, 10d nails are 0.148"dia. x 3" long.
New products or updated product information are designated in
blue font
.
Joist
Size
USP
Stock No.
Steel
Gauge
Dimensions (in)
2,
R12,
F1
Joist
Fastener Schedule
2,3
Header
Code
Ref.
DF/SP
Allowable
Loads (Lbs.)
1
JPF24
JPF Purlin Hangers
Top Face Floor
Uplift
1
Floor
Uplift
1
Ref. No. W H TF Qty Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
2 -- -- 10d 2 10d 1070 1070 1070 315 800 800 800 235
2 2 10d 2 10d 1275 1275 1275 470 950 950 950 350
2 -- -- 10d 2 10d 1070 1070 1070 315 800 800 800 235
2 2 10d 2 10d 1275 1275 1275 470 950 950 950 350
1) Uplift loads have been increased 60% for wind and seismic loads; no further increase shall be permitted.
2) JPF cannot be used back to back on a single ply header when optional nailing is used.
3) Minimum nail embedment shall be 1-1/2" for 10d nails.
4)
NAILS:
10d nails are 0.148" dia. x 3" long.
New products or updated product information are designated in
blue font
.
2,
R12,
F1
Roof
Code
Ref.
Purlin
Size
USP
Stock No.
Steel
Gauge
Roof
1-9/16
1-1/16
1-1/16
20 3-3/8
5-3/8
1-9/16
2 x 6 JPF26
Corrosion
Finish
PF26 20
2 x 4 JPF24 PF24
Dimensions (in)
Header
2
Joist
Fastener Schedule
3,4
DF/SP
Allowable Loads (Lbs.)
S-P-F
Allowable Loads (Lbs.)
Double shear nail design
features fewer nails and
faster installation
Uses standard
length nails
Typical JPF24
installation
Typical JPF24
back-to-back installation
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
TF
H
W
1-1/2"
Raised dimple
allows 30° to
45° nailing
Hangers