Technical Specifications

98
Angles & Straps
© 2015 MiTek. All rights reserved.
KHST / KRPS / PS
Strap Ties
KRPS – Meets IBC, IRC, & L.A. City requirements for notched plates
where plumbing, heating, or other pipes are placed in partitions.
PS – Piling Straps connect wood pilings to oor girders. Hot-dip
galvanized for corrosion protection in coastal environments.
KHST – Heavy-capacity strap that utilizes bolts.
Materials: See chart
Finish: KHST – USP primer; KRPS – G90 galvanizing;
PS – Hot-dip galvanized
Options: See chart for Corrosion Finish Options
Codes: See page 11 for Code Reference Chart
IRC R602.6.1, IBC 2308.9.8
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• Install one strap tie for each 2x plate.
Bolts must be ordered separately.
See page 24 for available sizes.
Typical KRPS
installation
KHST KRPS PS720-HDG
PS218-HDG
PS418-HDG similar
Typical PS720-HDG
installation
Ref. No.
WL
Qty Type Qty Type 160%
KHST2 HST2 7 2-1/2 21-1/4 -- -- -- -- -- -- 6 5/8 5250
KHST3 HST3 3 3 25-1/2 -- -- -- -- -- -- 6 3/4 7920
KHST5 HST5 7 5 21-1/4 -- -- -- -- -- -- 12 5/8 10635
KHST6 HST6 3 6 25-1/2 -- -- -- -- -- -- 12 3/4 15935
PS218-HDG PS218 7 2 18 -- -- -- -- -- -- 4 5/8 -- --
PS418-HDG PS418 7 4 18 -- -- -- -- -- -- 4 5/8 -- --
PS720-HDG PS720 7 6-3/4 20 -- -- -- -- -- -- 8 5/8 -- --
KRPS18 RPS18 16 1-1/2 18-5/16
<
5-1/2
12 16d -- -- -- --
1345
KRPS22 RPS22 16 1-1/2 22-5/16
<
5-1/2
16 16d -- -- -- --
1790
KRPS28 RPS28 16 1-1/2 28-5/16 <
12 16 16d -- -- -- --
1790
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) Allowable loads are based on single shear, parallel to grain loading with a 3-1/2" minimum member thickness
for KHST2 and KHST5, and 4-1/2" minimum member thickness for KHST3 and KHST6.
3) PS piling strap design loads must be determined for each installation. Bolts are installed perpendicular and
parallel-to-grain.
4)
NAILS:
16d nails are 0.162" dia. x 3-1/2" long.
blue font
.
120
14,
F7
Dimensions (in)
USP
Stock No.
3
Steel
Gauge
14,
R9,
F7
Nails Bolts
Fastener Schedule
4
Code
Ref.
DF/SP
Allowable Tension
Loads (Lbs.)
1,2
Notch
Width
(in)
Corrosion
Finish
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Piling
Built-up beam
KHST3 and KHST2
KHST6 and KHST5
KHST2
KHST3
KRPS18 & KRPS22 5-1/2"
KRPS28 12"
KHST5
KHST6
W
W
1-1/2"
3"
20"
1-1/4"
6-3/4"
3-3/4"
L
W
2-1/2
1"