Technical Specifications

200
Plated Truss
© 2015 MiTek. All rights reserved.
BN Breakfast Nook Hangers
Designed to carry four mono trusses in one connector, it reduces
installation time and cost. Provides a tested, load rated connection.
Standard conguration spacing: 22-1/2°, 45°, 45°, 45°, 22-1/2°.
The design also includes eld adjustable nailing tabs.
Materials: 14 gauge
Finish: USP primer
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• Allow a 2" setback for each mono truss.
For pitched ceiling, design mono trusses with end-vertical
upset. Upset equals tangent of the ceiling slope times 5.6".
Bend tab only once.
Typical DSC4R installation LDSC4L left shownDSC4R right shown
BN264
Standard conguration
(top view)
BN264
Typical BN264
installation
Floor
Uplift
1,2
Ref. No. L H B Qty Type Qty Type 100% 115% 125% 160%
BN264 THJM2-4-SDS3 14 10 5-3/8 3-1/4 20 10d 2 10d x 1-1/2 2380 2735 2975 645
BN284 -- -- 14 10 7-1/8 3-1/4 20 10d 2 10d x 1-1/2 2380 2735 2975 645
1
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
Maximum u
p
lift
p
er mono truss is 175 lbs. at 160% for DF/SP and 150 lbs. at 160% for S-P-F.
3
)
Loadin
g
p
ublished is for total load of connection.
4
)
Minimum nail
p
enetration is 1-1/2" for 10d nails.
5
)
NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" lon
g
, 10d nails are 0.148" dia. x 3" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
Code
Ref.
10, R8,
F5
Dimensions (in)
USP
Stock No.
Steel
Gauge
Roof
Carried Member
per Mono Truss
Fastener Schedule
4,5
Carrying
Member
DF/SP
Allowable Loads (Lbs.)
3
LDSC & DSC Drag Strut Connectors
Transfers lateral loads from girder truss into bearing walls.
Materials: See chart
Finish: USP primer
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
WS3 Wood Screw, 1/4" dia. x 3" long, are supplied with
DSC4 connector.
Compression Tension Compression Tension
Ref. No. Qty Type Qty Type 160% 160% 160% 160%
LDSC4L/R -- -- 14 9 10d x 1-1/2 9 10d x 1-1/2 1640 1640 1425 1425
DSC4L/R DSC5R/L-SDS3 3 16 WS3 16 WS3 4965 4945 4270 4250
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
3)
NAILS:
10d x 1-1/2" nails are 0.148" dia. x 1-1/2" long.
New products or updated product information are designated in
blue font
.
DF/SP
Allowable Loads (Lbs.)
1
S-P-F
Allowable Loads (Lbs.)
1
Fastener Schedule
2,3
10, R8,
F5
Code
Ref.
USP
Stock No.
Steel
Gauge
Truss Top Plate
Plated Truss
22-1/2°
Nailing tabs adjust
to fasten 22-1/2°
mono trusses
Field adjustable
nailing tabs with
slotted fastening
holes for slant
nailing
22-1/2°
45°
45°
45°
L
H
B
21"
10-1/2"
7"
3-1/4"
10-1/2"
2-1/8"
3"
2"

Summary of content (1 pages)