Technical Specifications
124
Hangers
© 2015 MiTek. All rights reserved.
RR
Ridge Rafter
The RR Ridge Rafter supports rafter pitches up to 7:12 (30°).
Nesting top ange for installation on 2x support beams.
Materials: 18 gauge
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• The rafter end at the ridge must be plumb cut to achieve
published loads.
• Optional diamond nail holes can be used to fasten RR to
end of rafter before setting rafter into place.
LSSH210
Typical RR
installation
Typical LSSH179
installation
LSSH35
RR
1-9/16"
Uplift
1"
Ref. No. Qty Type Qty Type 100% 115% 125% 100% 115% 125%
4 10d x 1-1/2 4 10d x 1-1/2 365 365 365 205 310 310 310 170
4 LL915 4 LL915 380 380 380 180 320 320 320 150
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2)
NAILS:
10d x 1-1/2 nails are 0.148" diameter x 1-1/2" long and LL915 denotes a USP LumberLok Screw, #9 x 1-3/8" long.
RR RR 18 2 x 6
USP
Stock No.
Steel
Gauge
Code
Ref.
130
Min
Rafter
Size
Download Download
Uplift
160%
Uplift
160%
DF/SP
Allowable Loads (Lbs.)
1
S-P-F
Allowable Loads (Lbs.)
1
Fastener Schedule
2
Header Rafter
4"
LSSH Slope/Skew Hangers
The LSSH series connects rafters to ridge beams in vaulted roof
structures. This series is eld adjustable to meet a variety of skew
and/or slope applications. Slopes and skews 0° to 45°.
Materials: See chart
Finish: G90 galvanizing; LSSH15-TZ – G-185 Galvanizing
Options: See Chart for Corrosion Finish Options
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
Steps:
1. Position LSSH connector against plumb-cut end of joist. Fasten
joist side anges on both sides with 10d (0.148") x 1-1/2" nails.
Bend seat up to t against joist bottom and drive (1)
10d (0.148") x 1-1/2" nail through bottom seat into rafter
bottom. Drive (2) 10d (0.148") x 1-1/2" nails at downward angle
through dimpled nailing guides.
2. Lean connector and rafter end against ridge beam at desired
position. Install specied 10d (0.148" dia. x 3") or 16d (0.162 x
3-1/2") nails through nail holes into ridge beam at right 90° angle. If
skewing the rafter, only drive nails into ridge beam on inside ange.
3. Bend ange to desired angle.
4. Hammer outside ange until edge touches header. Fasten outside
ange to ridge by driving specied 10d (0.148" dia. x 3") or 16d
(0.162 x 3-1/2") nails through nail holes.
• Web stiffeners are required for all wood I-Joist installations.
• Designer may consider adding a tension restraint for the
supported member for roof slopes exceeding 6/12. Refer to
pages 95-96.
Continued on next page
3-3/8"
LSSH15-TZ=5-1/16"
All other sizes = 8-13/16"
W2
W2
W1
W1
W2
W2
3"
3"
Slope to 45° up
or down
Slope to 45° up
or down
2
3 & 4
1
Skew to 45° maximum
H