Technical Specifications

182
Truss & Rafter
© 2015 MiTek. All rights reserved.
LUGT Girder Tiedowns
The LUGT series is an extremely adaptable tiedown for girder trusses and offers
several installation options to accommodate different framing conditions. It is an
ideal retrot solution to reinforce truss connections to transfer high wind loads
to supporting walls. Sizes available for 1-ply, 2-ply, 3-ply and 4-ply trusses.
Materials: See chart
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
All fastener holes must be lled with specied fasteners to achieve loads
listed in the chart. Large fastener holes are for concrete/masonry installations
(reference page 178) and do not need to be lled when used for girder-to-stud
applications.
• WS Wood Screws included with LUGT3 and LUGT4.
Typical LUGT2
installation
Typical LUGT1
installation
Typical LUGTC2
installation
LUGT1LUGTC2
Typical LUGT3 installation
(LUGT4 similar)
Uplift F1 F2 Uplift F1 F2
Ref. No. Qty Type Qty Type Qty Type 160% 160% 160% 160% 160% 160%
LUGT1 H10S 16 1 8 8d x 1-1/2 8 8d x 1-1/2 7 8d x 1-1/2 1065 650 310 895 545 260 110
LUGT2 LGT2 14 2 16 10d 2 10d 14 10d 2260 1015 505 1900 850 425
LUGTC2 -- -- 14 2 16 10d 2 10d 14 10d 2260 -- -- 575 1900 -- -- 480
LUGT3 LGT3-SDS2.5 12 3 12 WS25 4 16d Sinker 24 16d Sinker 3855 1980 890 3240 1660 745
LUGT4 LGT4-SDS3 12 4 16 WS3 5 16d Sinker 32 16d Sinker 4640 -- -- 3900 -- -- -- --
1
)
Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
Additional anchora
g
e
p
roducts to be desi
g
ned b
y
others.
3
)
For
p
ro
p
er installation, the number of studs must be e
q
ual-to or
g
reater-than the number of roof truss
p
lies.
4
)
NAILS: 8d x 1-1/2 are 0.131" dia. x 1-1/2" lon
g,
10d nails are 0.148" dia. x 3" lon
g,
16d Sinkers are 0.148" dia. x 3-1/4" lon
g,
WS25 Wood Screws are 1/4" dia. x 2-1/2" lon
g
(
su
pp
lied with LUGT3
)
and WS3 Wood Screws are 1/4" dia. x 3" lon
g
(
su
pp
lied with LUGT4
)
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
USP
Stock No.
Steel
Gauge
8, R10,
F4
110
No.
of
Plies
DF/SP
Allowable Loads (Lbs.)
1
S-P-F
Allowable Loads (Lbs.)
1
Fastener Schedule
2,3,4
Code
Ref.
Rafter/Truss Plate Stud
LUGT4LUGT3
LUGT2
12-7/8"
Uplift
F1
F2
6-3/4"
3-1/4"
3"
14-13/16"
Uplift
F2
3-3/16"
11-1/2"
1-5/8"
5"
3"
4-3/4"
6-1/4"
15-15/16"
5"
11-1/8"
16-1/8"
6-9/16"
12-7/8"