Technical Specifications
62
Holdowns
© 2015 MiTek. All rights reserved.
Typical PAI
I-Joist purlin face installation
PA / HPA PAI
Nails
Bolts
2
Nails
Bolts
2
Ref. No. Qty Nail Qty Dia. 160% 160% 160% 160%
Max Capacity
2x & 3x Ledger
4x Ledger
Max Capacity
2x & 3x Ledger
4x Ledger
Max Capacity
2x & 3x Ledger
4x Ledger
Max Capacity
2x & 3x Ledger
4x Ledger
Max Capacity
2x & 3x Ledger
4x Ledger
Max Capacity
2x & 3x Ledger
4x Ledger
Max Capacity 2475 2475
2x & 3x Ledger 2475 1855
4x Ledger 2270 1855
Max Capacity 3700
2x & 3x Ledger 3510
4x Ledger 3095
Max Capacity
2x & 3x Ledger
4x Ledger
Max Capacity
2x & 3x Ledger
4x Ledger
1) Allowable Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) The allowable loads for bolts are based on parallel-to-grain loading with 3" minimum member thickness, except HPA which
requires a 3-1/2" thick wood member.
3) Allowable loads are based on the use of either nails or bolts; nail and bolt values cannot be combined.
4) 16d sinkers or 10d common nails may be substituted for the specified 16d common nails at 0.85 of the table loads.
5) Minimum nail penetration is 1-5/8" for 16d nails.
6) For alternate nail schedule and load values consult USP.
7) Minimum quantity of fasteners to be installed. Product may have additional fastener holes not needed to meet published allowable load of product.
8)
NAILS:
10d x 1-1/2" nails are 0.148˝ dia. x 1-1/2" long, 16d nails are 0.162" dia. x 3-1/2" long.
6
6
8
3035
3035
3700
3035
-- --
-- --
-- --
-- --
3035
-- --
3700 30353700 3035
30353035
-- --
-- --
-- --
23 4
Code
Ref.
16d
130
Masonry
Concrete
Min Qty
7
Fastener Schedule
6
Minimum
Embedment
Nailer
Size
Nails
4,5,6
1/2
16d
16d
3
6
3035
3035
3035
3035
15 4
-- --
16d
3700
428050551/2
-- --
3700370015 416d 1/2
6
6
4280
3700
23 4 54251/2
26
-- --
-- --
18
-- --
24
10d x 1-1/2
12
-- --
10d x 1-1/2
8
10d x 1-1/2
-- -- 10d x 1-1/2
-- --
PAI23 PAI23 23-1/2 4
6
PAI28 PAI28 28-1/2 4
PAI35 PAI35 35-1/2
6
4
Concrete
HPA35 HPA35 35 6
PAI18 PAI18 18-1/2 4
4
PA28 PA28
PA35 PA35
HPA28 HPA28 29 6
29 4
35 4
L
(in)
DF/SP Allowable
Tension Loads (Lbs.)
1,3
USP
Stock No.
PA18 18-1/2 PA18
PA23 PA23 23-3/4
Bolts
22603035 303522601/2
Masonry
3265 30356
12 2
15
16d4
1/2
Corrosion
Finish
HPA / PA / PAI Purlin Anchors
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• Minimum concrete strength is 2,500 psi.
• The allowable loads for bolts are based on parallel to grain
loading with a 3" minimum member thickness, except the
HPA which requires a 3-1⁄2" thick wood member. Reduce
load per code requirements when minimum member
thickness is not achieved.
• Minimum concrete edge distance is 4" for PA & PAI series,
and 6" for HPA series.
• Minimum concrete block edge distance is 20".
• Designer may specify alternate fastening schedules. Refer
to Nail Specication Table on page 20 for nail shear values.
Load values shall not exceed published allowable loads.
• No anchor bolts are needed for achieving efcient stress
transfer from framing to concrete walls or foundations.
• Bolts must be ordered separately. See page 24 for available sizes.
L L
2-1/16"
2-1/16"
1-1/2"
4-1/2"
Ledger
4 min. concrete
20" min. concrete
block edge distance
#4 rebar
min
4"
Holdowns