Technical Specifications
220
General Hardware
© 2015 MiTek. All rights reserved.
PC / RC Plywood Clips
General Hardware
Steel plywood clips. All models feature
embossed dimples to provide 1/8" gap.
Materials: See chart
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Ref. No.
24 RC38-250 PSCL3/8 18 24 20 3/8 1
24 PC716 PSCL7/16 20 24 24 7/16 1
32 PC1532
PSCL15/32,
PSCA15/32
20 32 28 15/32 1
32 PC12 PSCL1/2 20 32 28 1/2 1
40 PC1932 PSCL19/32 20 40 32 19/32 2
40 PC58 PSCL5/8 20 40 32 5/8 2
48 PC34 PSCL3/4 20 48 36 3/4 2
1) Based on code specified allowable spans for panel sheathing continuous over
two or more spans with plywood strength axis perpendicular to supports.
2) Applicable to roof sheathing.
3) Applies to panels 24" or wider.
4) Uniform load deflection limitations 1/180 of span under live load plus dead load or
1/240 under live load only.
120
Plywood
Thickness
(in)
PC's
Per
Span
Maximum Span
1
Span
Rating
1
USP
Stock No.
Steel
Gauge
Code
Ref.
Without
PC
With
PC
Typical PC installation
Typical DC1 installation
Typical IS installation
PC
DC1
RC
Drywall clips or “stops” help support drywall or wood paneling
and reduce wood blocking on top plates, end walls, and corners.
Materials: 20 gauge
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Installation:
• Use 8d nails to install DC1, 16" on-center or less.
Insulation supports secure batt-type insulation in place between joists.
Chisel-cut ends dig into joists for permanent holding. Easy to install in
hard-to-reach crawl spaces.
Materials: 13 gauge carbon steel wire
Finish: None
Codes: See page 11 for Code Reference Chart
Installation:
• Use IS16 for joist spaced 16" O.C. and IS24 for 24" O.C. spacing.
• Position insulation batt in place between joists. Hold IS unit at the
center and push into place.
• Wear gloves and safety glasses during installation.
DC1 Drywall Clip
IS Insulation Supports
Ref. No. Qty Type
DC1 DS 20 1 8d 120
1
)
Minimum nail
p
enetration shall be 1-5/16" for 8d nails.
2
)
NAILS: 8d nails are 0.131" dia. x 2-1/2" lon
g
.
USP
Stock No.
Steel
Gauge
Fastener Schedule
1,2
Code
Ref.
Dimensions (in)
Ref. No. Overall Length
IS16 IS16-R100 13
16" O. C.
15-1/2"
IS24 IS24-R100 13
24" O. C.
23-1/2"
USP
Stock No.
Steel
Gauge
120
Code
Ref.
Joist
Spacing
1) Based on code specied allowable spans for panel
sheathing continuous over two or more spans with
plywood strength axis perpendicular to supports.
2) Applicable to roof sheathing.
3) Applies to panels 24" or wider.
4) Uniform load deection limitations 1/180 of span
under live load plus dead load or 1/240 under live
load only.
Provides
1/8" gap
3/4"
1-1/8"
1-1/2"
Simply push