Technical Specifications
152
© 2015 MiTek. All rights reserved.
EWP Hangers
PHM / PHXU Top Flange Hangers
Typical PHXU
installation
PHXU
PHM
Nailer Options
– chart represents maximum allowable loads for hangers used on wood
nailers. Reference page 140.
Specialty Options Chart
– refer to Specialty Options pages 228, 230-231 for additional details
Used to connect LVL, LSL, and PSL beams to headers in medium
load conditions using standard nails.
Materials: See EWP Top Mount Hangers charts, pages 153-160.
Finish: USP primer; PHXU – G90 galvanizing.
Codes: See page 11 for Code Reference Chart
Patents: #6,463,711 B1 – PHXU
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• For welded installations, see page 232.
Fastener Schedule
2
Uplift Uplift
Qty Type Qty Type 100% 160% 100% 160%
2X 2 10d x 1-1/2 2 10d x 1-1/2 3010 -- -- 2590 -- --
3X 2 16d x 2-1/2 2 10d x 1-1/2 3570 -- -- 3070 -- --
(2) 2X 2 10d 2 10d x 1-1/2 3325 -- -- 2860 -- --
4X 2 16d 2 10d x 1-1/2 3255 -- -- 2800 -- --
PHXU
1-3/4" widths
4X 8 16d 6 10d x 1-1/2
4420
1035 3805 890
4X 8 16d 6 10d x 1-1/2 5285 970 4545 835
4X 8 16d 6 10d 5285 1290 4545 1110
1) Listed loads shall not be increased.
2)
NAILS:
10d x 1-1/2" nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long,
16d nails are 0.162" dia. x 3-1/2" long.
New products or updated product information are designated in
blue font
.
S-P-F
Allowable Loads (Lbs.)
1
PHXU
width > 1-3/4"
PHM
Header Joist
USP
Series
Nailer
Size
DF/SP
Allowable Loads (Lbs.)
1
Option
Skewed
1,3,5
Sloped Seat
2,3
Sloped / Skewed
1,2,3
Sloped Top Flange
4
Saddle
5,6
Ridge
PHM 1˚ to 84˚ 0˚ to 45˚
PHXU 1˚ to 60˚ N/A
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.
2) Sloped or sloped/skewed hangers with slopes greater than 15° may have additional joist nails.
3) For skewed hangers, the required cut type (square or bevel) of joist member may vary based on skew angle
and width of hanger. Some square cut hangers will require custom pricing due to welded back plate.
4) Sloped top flanges with slopes greater than 15° may have additional header nails.
5) Skewed, top flange offset, or saddle options will have a solid, welded top flange.
6) Minimum header thickness shall be double the top flange (TF) dimension for 100% table load.
7) PHXU offset option - hanger will be welded with a closed top angle, not formed.
New products or updated product information are designated in
blue font
.
Range
Allowable
Loads
Add SK , angle required,
right (R) or left (L) , and
square cut
(SQ)
or
bevel cut
(BV)
to
product number.
Ex:
PHXU1795_SK45R_SQ
Ordering
PHXU
PHM
100% of table load
PHM
PHXU
100% of table load.
See footnote 6.
Add OS, and
right (R) or left (L),
to product number.
Ex:
PHXU1795_OSL
Add SL, slope
required,
and up (U) or
down (D), to
product number.
Ex:
PHXU1795_SL30D
See Sloped Seat
and Skewed.
Ex:
PHXU1795_SK45R_SQ_SL30D
Add SF, angle required,
and right (R) or left (L),
to product number.
Ex:
PHXU1795_SF30L
100% of table load
USP
Series
5-9/16"
to 7-1/2"
85%
Add DA, and angle
required to product
number.
Ex. PHXU1795_DA30
N/A
Top Flange Offset
5,7
See Sloped Seat
and Skewed
-- -- 0° to 35° -- -- 1˚ to 45˚
Add SA, and saddle
width required
to product number.
Ex:
PHXU1795_SA=5-1/2"
100% of table load
Reduce allowable table
loads using straight-line
interpolation
100% of table load up to
Max. load of 3900 lbs.
100% of table load up to
Max. load of 2500 lbs.
L
D
W
TF
EWP Hangers
L
D
W
H
TF
H