Technical Specifications
157
© 2015 MiTek. All rights reserved.
EWP Hangers
Top Mount Hanger Charts
Fastener Schedule
4,6
Uplift
2
DF/SP
Joist Size Ref. No. Ga W H D L TF Qty Type Qty Type LVL PSL LSL SPF DF/SP
160%
BPH3528 LBV3.56/28 x 12 3-9/16 28 2-3/4 -- 2-1/32 10 16d 6 10d 3430 3510 3775 3280 -- 3430 1140
2, R12,
F1
HBPH3528
HB3.56/28 x 10 3-9/16 28 3-1/2 -- 3 22 16d 10 16d 7000 7000 7000 7000 -- 7000 2705 2
PHM3528
HWI428,
WPI428
x 7/10 3-5/8 28 2-1/2 7 3 2 16d 2 10d 3745 3570 3080 3255 -- 3255 --
PHXU3528 WPU3.56/28 x 7 3-9/16 28 3-1/4 10 2-1/2 8 16d 6 10d 6650 5785 6420 3590 -- 5285 1290
BPH3530 LBV3.56/30 x 12 3-9/16 30 2-3/4 -- 2-1/32 10 16d 6 10d 3430 3510 3775 3280 -- 3430 1140
HBPH3530
HB3.56/30 x 10 3-9/16 30 3-1/2 -- 3 22 16d 10 16d 7000 7000 7000 7000 -- 7000 2705 2
PHM3530
HWI430,
WPI430
x 7/10 3-5/8 30 2-1/2 7 3 2 16d 2 10d 3745 3570 3080 3255 -- 3255 --
PHXU3530 -- -- x 7 3-9/16 30 3-1/4 10 2-1/2 8 16d 6 10d 6650 5785 6420 3590 -- 5285 1290
BPH3532 -- -- x 12 3-9/16 32 2-3/4 -- 2-1/32 10 16d 6 10d 3430 3510 3775 3280 -- 3430 1140
PHM3532
HWI432,
WPI432
x 7/10 3-5/8 32 2-1/2 7 3 2 16d 2 10d 3745 3570 3080 3255 -- 3255 --
PHXU3532 -- -- x 7 3-9/16 32 3-1/4 10 2-1/2 8 16d 6 10d 6650 5785 6420 3590 -- 5285 1290 130
THO20950-2
LBV4.12/9.5,
LBV4.28/9.5,
MIT4.28/9.5
x 16 4-3/16 9-1/2 3 -- 2 10 16d 6 10d 2330 2665 2665 2240 2630 2665 1115
PHM4295 -- -- x 7/10 4-3/16 9-1/2 2-1/2 7 3 2 16d 2 10d 3745 3570 3080 3255 -- 3255 --
THO20118-2
LBV4.12/11.88,
LBV4.28/11.88,
MIT4.28/11.88
x 16 4-3/16 11-7/8 3 -- 2 10 16d 6 10d 2330 2700 2700 2270 2630 2700 1115
PHM42118 -- -- x 7/10 4-3/16 11-7/8 2-1/2 7 3 2 16d 2 10d 3745 3570 3080 3255 -- 3255 --
THO20140-2
LBV4.12/14,
LBV4.28/14,
MIT4.28/14
x 12 4-3/16 14 3 -- 1-15/16 10 16d 6 10d 2330 3700 3700 2765 2630 3700 1175
PHM4214 -- -- x 7/10 4-3/16 14 2-1/2 7 3 2 16d 2 10d 3745 3570 3080 3255 -- 3255 --
THO20160-2
LBV4.12/16,
LBV4.28/16
x 12 4-3/16 16 3 -- 1-15/16 10 16d 6 10d 2330 3700 3700 2765 2630 3700 1175
PHM4216 -- -- x 7/10 4-3/16 16 2-1/2 7 3 2 16d 2 10d 3745 3570 3080 3255 -- 3255 --
THO23950-2
LBV4.75/9.5,
MIT359.5-2
x 12 4-3/4 9-1/2 3 -- 2 10 16d 6 10d 3535 3635 3635 2675 2630 3665 1175
PHM2395-2 WP359.5-2 x 7/10 4-3/4 9-1/2 2-1/2 7 3 2 16d 2 10d 3745 3255 2965 3255 -- 3255 --
THO23118-2
LBV4.75/11.88,
MIT3511.88-2
x 12 4-3/4 11-7/8 3 -- 2-1/8 10 16d 6 10d 3535 3665 3665 3005 2630 3665 1175
PHM23118-2 WP3511.88-2 x 7/10 4-3/4 11-7/8 2-1/2 7 3 2 16d 2 10d 3745 3255 2965 3255 -- 3255 --
4-1/2 - 4-5/8 x 14 THO23140-2
LBV4.75/14,
MIT3514-2,
WP3514-2
x 12 4-3/4 14 3 -- 2-1/8 12 16d 6 10d 3535 4405 4405 3265 2630 4450 1175
THO23160-2 LBV4.75/16 x 12 4-3/4 16 3 -- 2-1/8 12 16d 6 10d 3535 4405 4405 3265 2630 4450 1175
PHM2316-2 WP3516-2 x 7/10 4-3/4 16 2-1/2 7 3 2 16d 2 10d 3745 3255 2965 3255 -- 3255 --
THO23180-2 LBV4.75/18 x 12 4-3/4 18 3 -- 2-1/8 14 16d 6 10d 3535 4685 4685 3520 2630 4770 1175
PHM2318-2 WP3518-2 x 7/10 4-3/4 18 2-1/2 7 3 2 16d 2 10d 3745 3255 2965 3255 -- 3255 --
THO23200-2 LBV4.75/20 x 12 4-3/4 20 3 -- 2-1/8 14 16d 6 10d 3535 4685 4685 3520 2630 4770 1175
PHM2320-2 WP3520-2 x 7/10 4-3/4 20 2-1/2 7 3 2 16d 2 10d 3745 3255 2965 3255 -- 3255 --
1) When I-joist is used as a header, all nails must be 10d x 1-1/2.
2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted
3) Some listed loads may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
4) Minimum nail penetration shall be 1-1/2" for 10d nails and 1-5/8" for 16d nails.
5) When I-Joists with flanges less than 1-1/2" thick are used as headers, the published capacity shall be reduced. Contact USP for additional information.
6)
NAILS:
10d x 1-1/2" nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, 16d nails are 0.162" dia. x 3-1/2" long.
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
New products or updated product information are designated in
blue font
.
2,
R12,
F1
4 - 4-3/16 x
11-7/8
4 - 4-3/16 x
9-1/2
2,
R12,
F1
Code
Ref.
2,
R12,
F1
4-1/2 - 4-5/8 x 20
4-1/2 - 4-5/8 x 16
4-1/2 - 4-5/8 x 18
4 - 4-3/16 x 14
4 - 4-3/16 x 16
4-1/2 - 4-5/8 x
9-1/2
4-1/2 - 4-5/8 x
11-7/8
Allowable Loads Header Type (Lbs.)
1,3
3-1/2 x 32
Header Joist Download 100%
DF
I-Joist
5
3-1/2 x 28
3-1/2 x 30
Dimensions (in)
USP
Stock No.
Web
Stiff
Reqd
EWP Hangers
H
W
L
TF
D