1
Joist Size Ref. No. W H D A Qty Nail Qty Nail 100% 115% 125% 160%
4 10d 2 10d x 1-1/2 470 540 580 320
4 16d 2 10d x 1-1/2 560 640 695 320
4 10d HDG 2 10d x 1-1/2 HDG 465 535 580 280
4 16d HDG 2 10d x 1-1/2 HDG 550 615 615 280
JUS24 LUS24 18 1-9/16 3-1/8 1-3/4 1 4 10d 2 10d 675 775 835 510
4 10d 2 10d x 1-1/2 500 560 605 380
4 16d 2 10d x 1-1/2 590 665 720 380
HD26 HU26 14 1-9/16 3-1/2 2 1-1/8 4 16d 2 10d x 1-1/2 565 650 705 290
6 10d 4 10d x 1-1/2 710 805 870 650
6 16d 4 10d x 1-1/2 840 960 1045 650
6 10d HDG 4 10d x 1-1/2 HDG 695 800 870 730
6 16d HDG 4 10d x 1-1/2 HDG 830 950 1035 730
JUS26 LUS26 18 1-9/16 4-13/16 1-3/4 1 4 10d 4 10d 870 1000 1080 1115 5, R5, F2
MUS26 MUS26 18 1-9/16 5-1/16 2 1 6 10d 6 10d 1285 1475 1605 865 31, R1, F32
6 10d 4 10d x 1-1/2 750 840 910 755
6 16d 4 10d x 1-1/2 880 1000 1080 755
HUS26 HUS26 16 1-5/8 5-7/16 3 2 14 16d 6 16d 2760 3140 3345 1925
HD26 HU26 14 1-9/16 3-1/2 2 1-1/8 4 16d 2 10d x 1-1/2 565 650 705 290
HD28 HU28 14 1-9/16 5-1/4 2 1-1/8 8 16d 4 10d x 1-1/2 1130 1295 1410 730
6 10d 4 10d x 1-1/2 710 805 870 650
6 16d 4 10d x 1-1/2 840 960 1045 650
6 10d HDG 4 10d x 1-1/2 HDG 695 800 870 730
6 16d HDG 4 10d x 1-1/2 HDG 830 950 1035 730
10 10d 6 10d x 1-1/2 1180 1295 1295 855
10 16d 6 10d x 1-1/2 1400 1600 1740 855
8 10d HDG 4 10d x 1-1/2 HDG 930 1065 1160 730
8 16d HDG 4 10d x 1-1/2 HDG 1105 1215 1215 730
JUS26 LUS26 18 1-9/16 4-13/16 1-3/4 1 4 10d 4 10d 870 1000 1080 1115
JUS28 LUS28 18 1-9/16 6-5/8 1-3/4 1 6 10d 4 10d 1110 1270 1375 1115
MUS26 MUS26 18 1-9/16 5-1/16 2 1 6 10d 6 10d 1285 1475 1605 865
MUS28 MUS28 18 1-9/16 7-1/16 2 1 8 10d 8 10d 1710 1970 2140 1230
6 10d 4 10d x 1-1/2 750 840 910 755
6 16d 4 10d x 1-1/2 880 1000 1080 755
8 10d 6 10d x 1-1/2 1000 1120 1210 800
8 16d 6 10d x 1-1/2 1175 1335 1440 800
HUS26 HUS26 16 1-5/8 5-7/16 3 2 14 16d 6 16d 2760 3140 3345 1925
HUS28 HUS28 16 1-5/8 7-3/16 3 2 22 16d 8 16d 4170 4345 4345 2570
HD28 HU28 14 1-9/16 5-1/4 2 1-1/8 8 16d 4 10d x 1-1/2 1130 1295 1410 730
HD210 HU210 14 1-9/16 7-3/16 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730
1
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
Minimum nail embedment shall be 1-1/2" for 10d nails and 1-5/8" for 16d nails.
3
)
16d sinkers
(
0.148 dia. x 3-1/4" lon
g)
ma
y
be used at 0.84 of the table load where 16d commons are s
p
ecified. This does not a
pp
l
y
to JUS, HUS, MUS slant nail han
g
ers.
4
)
For JUS, HUS, and MUS han
g
ers: Nails must be driven at a 30° to 45˚ an
g
le throu
g
h the
j
oist or truss into the header to achieve the table loads.
5
)
NAILS: 10d x 1-1/2" nails are 0.148" dia. x 1-1/2" lon
g,
10d nails are 0.148" dia. x 3" lon
g,
16d nails are 0.162" dia. x 3-1/2" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
Dimensions (in)
USP
Stock No.
Steel
Gauge
Roof
Code
Ref.
Corrosion
Finish
Fastener Schedule
2,3,5
Header Joist
DF/SP
Allowable Loads (Lbs.)
4
16 1-9/16 3-1/4 2 1-3/16
20 1-9/16 3 1-1/2 15/16
LUC26Z
31, R1,
F32
5,
R5,
F2
5,
R5,
F2
5,
R5,
F2
20 1-9/16 4-3/4 1-1/2 15/16
1-9/16 4-1/218 1-1/2 -- --
2 1-3/16
16 1-9/16
18 1-9/16 1-1/2 -- --
16 1-9/16
2 1-3/16
2 x 4
JL24 LU24
5,
R5, F2
JL24IF-TZ -- --
31, R1,
F32
SUH24 U24
18 1-9/16 3-1/8 1-1/2 -- --
5, R5, F2
31, R1,
F32
16 1-9/16 5-1/8 2 1-3/16
20 1-9/16 4-3/4
31, R1,
F32
5, R5, F2
1-1/2
18 1-9/16 4-1/2 1-1/2
15/16
-- --
20 6-3/8 1-1/2 15/16
31, R1,
F32
6-5/8
5-1/8
SUH26 U26
JL26IF-TZ
2 x 8
JL26 LU26
JL26IF-TZ LUC26Z
JL28
SUH26 U26
SUH28 -- --
LU28
2 x 6
JL26 LU26
1-9/16
6-1/8 JL28IF-TZ -- --
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Continued on next page
A
D
H
W
Hangers